ACR Systems SRP-003-5V-128K
SmartReader Plus 3 8-Channel (Temperature and External 0-5V DC) Data Logger with 128 KB Memory
ACR Systems SRP-003-5V-128K
SmartReader Plus 3 8-Channel (Temperature and External 0-5V DC) Data Logger with 128 KB Memory
The ACR Systems SRP-003-5V-128K SmartReader Plus 3 is an 8-Channel (Temperature and External 0-5V DC) Data Logger with 128 KB Memory for recording AC current and voltage. It has 1 channel for ambient temperature, 4 channels for AC current, and 3 channels for AC voltage. With built-in menus for sample rate and mode, start delay, equations and more, logger setup is fast and easy.
- Operate with TrendReader 2 Software
- Number of Channels: 8
- Memory Size: 128 KB
- Note: SmartReader Data Loggers require TrendReader 2 Software to operate
- Note: Probes, transformers and transducers not included
- Number of Channels: Eight (8)
- One (1) channel for ambient temperature
- Four (4) channels for AC current (with ACR current probes)
- Three (3) channels for AC voltage (with ACR voltage transducers, single phase or 3-phase)
- Monitor and record current and voltage (single or 3-phase)
- Determine energy consumption
- Memory Size: 128 KB
- 12-bit resolution
- 10-year battery life
- 3-year warranty
- Fast sample rates
- Remote access via modem or Ethernet
- Network capable (connect up to 10 data loggers)
- Alarm dial-out
- User configurable
- Case Material: Noryl plastic
- External Connector: Removable screw-type terminal strip with Common (-) connection
- Mounting: Magnetic backing or locking eyelet
- Operating Limits: -40 to 70°C (-40 to 158°F) and 0 to 95% relative humidity (non-condensing)
- Clock Accuracy: +/- 2 seconds per day
- Battery: 3.6 volt Lithium, 1 Amp-Hour
- Battery Life: 10 years under normal use (factory replaceable)
- Power Consumption: 5 to 10 microamps (continuous)
- Sampling Methods:
- Continuous (First-in, First-out - not available with sample rates faster than 8 seconds)
- Stop when full (Fill-then-stop)
- Sampling Rates: User selectable rates from 25 per second (0.04 seconds) to once every 8 hrs
- Resolution: 12-bit (1 part in 4,096)
Internal Temperature Sensor
- Type: Negative Temperature Coefficient Thermistor 10,000 ohms @ 25°C (77°F)
- Range: -40 to 70°C (-40 to 158°F)
- Accuracy: +/- 0.2°C over the range of 0 to 70°C (+/- 0.3°F over range of 32 to 158°F)
- Resolution: 0.03°C at 25°C (0.05°F at 77°F); better than 0.07°C (0.12°F) between -25 and 70°C (-13 and 158°F); better than 0.13°C (0.23°F) between -40 and -25°C (-40 and -13°F)
- Internal Temperature Sensor
- Type: Negative Temperature Coefficient Thermistor 10,000 ohms @ 25°C (77°F)
- Range: -40 to 70°C (-40 to 158°F)
- Accuracy: +/- 0.2°C over the range of 0 to 70°C (+/- 0.3°F over the range of 32 to 158°F)
- Resolution: 0.03°C at 25°C (0.05°F at 77°F); better than 0.07°C (0.12°F) between -25 and 70°C (-13 and 158°F); better than 0.13°C (0.23°F) between -40 and -25°C (-40 and -13°F)
- Current Ranges:
- 5, 25, 100, and 250 Amps with A60FL (60 Hz) and A65FL (50 Hz) current probes
- 10, 50, 250, and 500 Amps with A70FL (60 Hz) and A75FL (50 Hz) current probes
- Up to 3000 Amps with ACR CT-50-2 current transformer
- Nominal Voltage Ranges:
- 120 V (1 phase, 60 HZ)
- 480 V (3 phase, 60 HZ)
- Accuracy:
- Voltage Channels: +/- 0.5% F.S.
- Current Channels: +/- 3.5% F.S. above lowest 10% of range
Applications
- Determining energy consumption
- Monitoring 3-phase voltage and current
- Start-up or long-term load analysis
- Demand side management
- Electric motor maintenance scheduling
The ACR Systems SmartReader Plus 3 (SRP-003-5V-128K) 8-Channel (Temperature and External 0-5V DC) Data Logger with 128 KB Memory easily and accurately records AC current and voltage. Simply connect ACR's current probes (which are clamped around the power leads) and ACR's voltage transducer to the data logger and begin recording. From the data collected, you can even determine energy consumption (kWh) using ACR's powerful, versatile and easy to use software, TrendReader 2.
TrendReader 2 Software
The ACR Systems TrendReader 2 Software is a powerful, versatile and easy-to-use application, designed exclusively for ACR's SmartReader Plus, SmartReader, IAQ, OWL, TRH, JR and Nautilus data loggers. Powerful features and easy setup enables collected data to be thoroughly analyzed in seconds.
Downloading and Communicating with Data Logger
Setup, download and view information from a single data logger with ACR's IC-102 interface cable (included in software interface package). Connection is simple; plug the interface cable into the USB port of your computer and connect the other end to the logger. No tools, cards or docking stations are required.
Data Logger Setup
With built-in menus for sample rate and mode, start delay, equations and more, logger setup is fast and easy. In addition, equations are already included for all ACR sensors so you need only select the appropriate equation from the menu or customize your own. Real-time readings are displayed in the Setup window, allowing you to verify that your data logger is working correctly before placing it in the field.
Viewing Data
With TrendReader 2, data can be viewed in several ways. For presentation purposes, view your collected data in graphical format or for a more detailed analysis, view your data in table format. Either way, multiple channels of data can be displayed at once. Multiple graphs can be displayed together and compounded to create new graphs. For added presentation power, add comments, change graph colors, zoom in on specific portions of data, and display your data using custom engineering units. Print or copy and paste graphs into your reports and presentations. Select all, or portions of the table and copy and paste into your favorite Windows program.
Exporting Data
Use the export function in TrendReader 2 to export your data to other programs for further analysis. Data can be exported in TXT, BMP, PDF, JPG or CSV formats.
Brand | ACR |
---|---|
Catalog | 01-0140 |
Condition | NEW |
Vendor Alias | 01-0140 |