ACR Systems SRP-009-128K
SmartReader Plus 9 2-Channel External Pulse Signals/Dry Switch Contact Closure Data Logger with 128 KB Memory
ACR Systems SRP-009-128K
SmartReader Plus 9 2-Channel External Pulse Signals/Dry Switch Contact Closure Data Logger with 128 KB Memory
The ACR Systems SRP-009-128K SmartReader Plus 9 is a 2-Channel (External Pulse Signals/Dry Switch Contact Closure) Data Logger for easy counting and recording of digital pulses or switch contact closures. Setup and view information with the IC-102 interface cable. With built-in menus, it has two pulse/contact input channels.
- Operate with TrendReader 2 Software
- Count up to 4095 pulses per sample period
- Memory Size: 128 KB
- 12-bit resolution
- Note: SmartReader Data Loggers require TrendReader 2 Software to operate
- Note: Probes, transformers and transducers not included
- Number of Channels: Two (2)
- Two (2) channels for externally-generated pulse signals and dry switch contact closures
- Count and record digital pulses or switch contact closures (i.e. on/off, open/close)
- Select slow or fast input
- Count up to 4095 pulses per sample period
- Memory Size: 128 KB
- 12-bit resolution
- 10-year battery life
- 3-year warranty
- Fast sample rates
- Remote access via modem or Ethernet
- Network capable (connect up to 10 data loggers)
- Alarm dial-out
- User configurable
- Case Material: Noryl plastic
- External Connector: Removable screw-type terminal strip with Common (-) connection
- Mounting: Magnetic backing or locking eyelet
- Operating Limits: -40 to 70°C (-40 to 158°F) and 0 to 95% relative humidity (non-condensing)
- Clock Accuracy: +/- 2 seconds per day
- Battery: 3.6 volt Lithium, 1 Amp-Hour
- Battery Life: 10 years under normal use (factory replaceable)
- Power Consumption: 5 to 10 microamps (continuous)
- Sampling Methods:
- Continuous (First-in, First-out - not available with sample rates faster than 8 seconds)
- Stop when full (Fill-then-stop)
- Sampling Rates: User selectable rates from 25 per second (0.04 seconds) to once every 8 hrs
- Resolution: 12-bit (1 part in 4,096)
Pulse Inputs
- Range: 4095 pulses/sample period
- Accuracy: +/- 1 pulse/sample period
- Max Voltage: +24/-22 volts DC
- Input Impedance: > 1.0 M ohm for Vin < 5V; > 4.0 K ohm for Vin > 5V
- Min. Pulse Wide:
- 50% Duty Cycle:
- Slow input: 2 milliseconds
- Fast input: 10 microseconds
- 50% Duty Cycle:
- Voltage Inputs:
- Input type:Active logic signals
- Input voltage:Low = 0 to 0.5 volts DC
- High = 4.5 to 24 volts DC
- Switch Inputs:
- Input Type: Uncommitted "dry" contacts (relay or switch)
- Excitation: 5 microamps contact current; 3.6 volts open circuit
- Contacts:
- Sealed gold-plated recommended
- Maximum Frequency: 100 KHz
- Memory Size: 128 KB
Applications
- Monitoring fluid and air flow, energy use, wind speed, shaft RPM, and rainfall
The ACR Systems SmartReader Plus 9 (SRP-009-128K) 2-Channel External Pulse Signals/Dry Switch Contact Closure Data Logger with 128 KB Memory is a versatile, designed for easy counting and recording of digital pulses or switch contact closures. It has two pulse/contact input channels. Data can be displayed in custom engineering units using the simple equation editor of ACR's TrendReader 2 software.
TrendReader 2 Software
The ACR Systems TrendReader 2 Software is a powerful, versatile and easy-to-use application, designed exclusively for ACR's SmartReader Plus, SmartReader, IAQ, OWL, TRH, JR and Nautilus data loggers. Powerful features and easy setup enables collected data to be thoroughly analyzed in seconds.
Downloading and Communicating with Data Logger
Setup, download and view information from a single data logger with ACR's IC-102 interface cable (included in software interface package). Connection is simple; plug the interface cable into the USB port of your computer and connect the other end to the logger. No tools, cards or docking stations are required.
Data Logger Setup
With built-in menus for sample rate and mode, start delay, equations and more, logger setup is fast and easy. In addition, equations are already included for all ACR sensors so you need only select the appropriate equation from the menu or customize your own. Real-time readings are displayed in the Setup window, allowing you to verify that your data logger is working correctly before placing it in the field.
Viewing Data
With TrendReader 2, data can be viewed in several ways. For presentation purposes, view your collected data in graphical format or for a more detailed analysis, view your data in table format. Either way, multiple channels of data can be displayed at once. Multiple graphs can be displayed together and compounded to create new graphs. For added presentation power, add comments, change graph colors, zoom in on specific portions of data, and display your data using custom engineering units. Print or copy and paste graphs into your reports and presentations. Select all, or portions of the table and copy and paste into your favorite Windows program.
Exporting Data
Use the export function in TrendReader 2 to export your data to other programs for further analysis. Data can be exported in TXT, BMP, PDF, JPG or CSV formats.
Brand | ACR |
---|---|
Catalog | 01-0130 |
Condition | NEW |
Vendor Alias | 01-0130 |