Additel ADT875PC-350-G-110V

Dry Well Calibrator with Insert G and Process Calibrator Option, 33°C to 350°C, 110V

ADT875PC350G110V
ADT875PC-350-G-110V

Additel ADT875PC-350-G-110V

Dry Well Calibrator with Insert G and Process Calibrator Option, 33°C to 350°C, 110V

ADT875PC350G110V
ADT875PC-350-G-110V
  • Brand Name: Additel
  • Condition: NEW
This product is available for shipping to the US, Canada, and Puerto Rico only.
$9,534.00
This item ships FREE
  • Portable, rugged, and quick to temperature
  • Metrology-level performance in stability, uniformity, accuracy and loading effect
  • Dual-zone control
  • Color touch screen display
  • Set point control by reference
  • Self-calibration feature
  • Process calibrator option provides a multi-channel readout for a reference thermometer, RTDs and TCs, task documentation, and HART communication
  • Power: 110V
  • Temperature range at 23°C: 33°C to 350°C
  • Display accuracy: ±0.2°C at Full Range
  • Stability (30 min): ±0.02°C at Full Range
  • Axial uniformity at 60mm: ±0.04°C at 33°C; ±0.1°C at 200°C; ±0.2°C at 350°C
  • Radial uniformity: ±0.01°C at 33°C; ±0.015°C at 200°C; ±0.02°C at 350°C
  • Loading effect: ±0.15°C (Display Sensor); ±0.015°C (External Sensor)
  • Insert model: G

The Additel ADT875PC-350-G-110V Dry Well Calibrator with Insert G and Process Calibrator Option, 33°C to 350°C, 110V combines excellent performance in stability, radial and axial uniformity, and loading with speed, ruggedness and portability. The Process Calibrator option adds the capabilities of a three-channel thermometer readout and a documenting process calibrator.Process Calibrator Option

The process calibrator option combines the many features found in a HART documenting process calibrator with the temperature dry well. This option includes the ability to measure a reference PRT and two device under test channels which can measure, mA, voltage, switch, RTD or thermocouple. In addition to these measurement functions, this calibrator has full documenting capability of creating tasks, saving as found and as left results, and HART communication. The snap shot feature allows you to capture all information displayed on the screen with the push of a button. This optional add-on allows for data logging of all channels on an auto step function and a ramp function. By utilizing the reference PRT, you can select to control to the dry well set point using the internal sensor or the external reference PRT.

Self-Calibration

Using an external reference probe as your standard is the best way to perform your temperature calibration. But this method is not always necessary or convenient and depending on the application, using the internal control sensor would be preferred. Traditionally, the internal control sensor has a wide accuracy which can largely be contributed to its long-term drift. The ADT875PC-350-G-110V has a built-in self-calibration feature allowing you to run an automated calibration of the internal control sensor using your external reference. With literally a few selections the calibration will run automatically giving you a fresh, traceable calibration of the control sensor which will improve its accuracy as you will not have to account for its long term drift when used as the reference.

More Information
BrandAdditel
ConditionNEW
Vendor AliasADT875PC-350-G-110V
  • 1 - Insert G
  • 1 - Power Adapter
  • 1 - USB Cable
  • 1 - Insert Removal Tool
  • 1 - Thermal Shield
  • 1 - Silica Gel Plug Set
  • 1 - Insulation Plug
  • 2 - Test Lead Sets
  • 1 - Certificate of Calibration
  • 1 - CD Manual