AEMC PEL 52 w/o Sensors

Split-Phase Power and Energy Logger with LCD Display, No Sensors

PEL52WOSENSORS
PEL 52 w/o Sensors

AEMC PEL 52 w/o Sensors

Split-Phase Power and Energy Logger with LCD Display, No Sensors

PEL52WOSENSORS
PEL 52 w/o Sensors

The AEMC PEL 52-W/O-SENSORS (2137.71) Split-Phase Power and Energy Logger is suited for both single and split-phase applications. Designed for electricians, engineers, and contractors, this unit allows for measurement, recording, and analysis of crucial energy data for improved electrical consumption.

  • LCD with blue backlight
  • No Sensors
  • Built-in magnets for mounting inside electrical cabinets
  • Compact, rugged, water/shock-proof casing
  • Simple-to-use, portable, single, dual (split phase) power/energy data logger
  • Provides precise readings over time to make accurate assessments of energy consumption
  • Real-time monitoring to identify patterns, monitor changes, make informed decisions to optimize energy usage
  • Works with wide range of electrical equipment, systems, residential, light commercial single/split phase measurements
  • Capable of performing load studies in compliance with NEC 220.87
  • Log data over extended period to analyze historical trends/identify areas for improvement
  • Rugged/durable for withstanding demands of real-world applications
  • Wide backlit LCD display
  • Install without cutting off electrical networks being monitored
  • Vital energy data is easily measured, recorded, analyzed
  • True-RMS voltage/current measurement up to 600V
  • Powered via measuring phase
  • Measurement of AC phase currents (11, 12) (sensor-dependent)
  • RMS AC measurements (50 Hz/60 Hz), aggregation every second without missing measurements
  • Easy to use, automatic recognition of current sensors
  • W, VA, var (P, 0, S, N, D) power measurements
  • Calculation of Cos/Power Factor (DPF)
  • Aggregation measurements over period of 1 minute to 1 hour
  • Storage of 1s/aggregated measurements on SD/SDHC card, data can be read directly on PC
  • Remote connectivity via IRD server
  • Integrated web server for remote viewing (Android, iOS, Windows)
  • Wi-Fi offers accessibility to diagnose problems in real-time/multi-station operation
  • Data saved on SD card for easier transport
  • DataView software included for configuring, data retrieval, real-time measurement display, data analysis, report generation
  • Compact casing with built-in magnets to facilitate mounting for easier implementation in electrical cabinets
  • Environmental aspects considered during product development to make lowest possible environmental impact throughout product life cycle
Applications
  • Load surveys, determine how much energy each item of equipment consumes operating at MIN/MAX power level
  • Energy analysis, estimate energy consumption before/after improvements
  • Energy surveys, measurements for energy surveys must be performed at several locations on evaluation sites
Specifications
  • Inputs: 2V/2I
  • Type of Installations: Single phase, split phase, 2 single-phase channels
  • Recording/Data Storage Rate: Unlimited duration, 4 GB max. recording size/1 sec. to 1 hr. (Min/Avg/Max)
  • Network Frequency: 45 to 65 Hz
  • Voltage: 10 to 600V
  • Communication: Wi-Fi access point/hot spot
  • Display Type: LCD with blue backlight

The AEMC PEL 52-W/O-SENSORS (2137.71) Split-Phase Power and Energy Logger represents an user-friendly power and energy data logger, suitable for both single and split-phase applications. This unit is specifically designed for electricians, engineers, and contractors working in residential and light commercial areas. This device allows effortless measurement, recording, and analysis of crucial energy data. Generating reports requires minimal configuration time and effort and includes the added benefit of having standard and customizable report options available.

The AEMC PEL 52-W/O-SENSORS (2137.71) Split-Phase Power and Energy Logger has a large, backlit LCD display for crisp viewing and an SD card to store measurements. This unit is designed to operate in 600V CAT III or lower environments. The PEL 52-W/O-SENSORS (2137.71) records voltage, current, power, and energy on alternating current distribution networks of 50 Hz or 60 Hz. The instrument is compact enough to fit into many different distribution panels, has a water and shock resistant housing, operates on phase 1 input, and has a backup battery that charges from the V1 input during measurements.

The instrument’s design enables it to be installed inside a load center panel-- including the current sensors-- allowing the door to close on most panels. The AEMC PEL 52-W/O-SENSORS (2137.71) Split-Phase Power and Energy Logger measures and records one or two True-RMS voltage inputs up to 690 volts, current inputs up to 3600 amps (sensor dependent), watts, VARS, VA, and energy for both kWh and kVA. Power Factor (PF), Displacement Power Factor (DPF), and Frequency are calculated and recorded as well. All variables are recorded and stored at an one second interval and on user-selectable demand intervals from 1 to 60 minutes.

By combining energy-saving techniques with detailed power consumption monitoring, residential and commercial builders can gain valuable insights into their energy usage, pinpoint areas for improvement, and monitor their advancements in energy conservation efforts. Ultimately, this results in decreased energy expenses, a diminished environmental footprint, and improved operational efficiency.

More Information
BrandAEMC
ConditionNEW
  • 1 - Split-Phase Power/Energy Logger (PEL 52)
  • 3 - Test Leads with Alligator Clip, Black
  • 1 - Carrying Bag
  • 1 - Power Cord, 115V, 5 ft.
  • 1 - Power Cord Adapter
  • 1 - SD Card
  • 1 - USB SD Card Adapter
  • 1 - USB Drive with DataView Software, 4 GB
  • 2 - AAA Rechargeable Batteries
  • 1 - Safety Sheet
  • 1 - User Manual
  • 1 - Quick-Start Guide
  • 1 - Compliance Sheet
  • 1 - Battery Information Sheet