CCS Products RWNB-3D-240-P

Wattnode Pulse Meter, Delta, 208-240 VAC Line to Line, Revenue Model

RWNB3D240P
RWNB-3D-240-P

CCS Products RWNB-3D-240-P

Wattnode Pulse Meter, Delta, 208-240 VAC Line to Line, Revenue Model

RWNB3D240P
RWNB-3D-240-P
  • VAC line to line: 208-240
  • 3 phase
  • 3-4 wire
  • VAC line to line: 208-240
  • 3 phase
  • 3-4 wire
  • Accuracy: 0.5% nominal
  • Electrical service types: Single-Phase 208V (No neutral), Single-Phase 240V (No neutral), Single-Phase 3-Wire 120/240V, 3-Phase 3-Wire Delta 208V-240V (No neutral), 3-Phase 4-Wire Wye 120/208V
  • Meets the accuracy requirements of the ANSI C12.1 standard for revenue grade applications when used with revenue grade CTs
  • Pulse output: Compatible with energy management systems and data loggers
  • Small size: Can be installed in existing service panels or junction boxes
  • Bidirectional metering: Net metering for PV (photovoltaic) solar and wind power generation with only one meter
  • Advanced metering design: Enables metering of inverters and variable frequency drives
  • Line powered: No external supply required
  • UL, cUL Listed
  • Detachable terminal blocks: Easy to install and remove
  • Pulse output: Opto-isolated, 5000 volt rated solid state relay (dry contact rated 60 Vdc at 5 mA)
  • Full-scale bidirectional pulse outputs standard 4.0 pulses per second resolution
  • Line powered
  • Operating Voltage Range: -20%, +15% of nominal
  • Power Line Frequency: 50 or 60 Hz
  • CT Input: 0.333 Vac nominal, 3 Vac maximum

The CCS Products RWNB-3D-240-P WattNode Pulse Meter, Delta, 208-240 VAC Line to Line, Revenue Model is a true RMS AC watt-hour transducer with pulse output (solid state relay closure) proportional to kWh consumed or produced. The WattNode Pulse meter provides 0.5% accurate kWh measurements at low cost to meet needs for sub-metering, net-metering, energy management, and performance contracting applications. Diagnostic LEDs provide a per-phase indication of line voltage, positive energy (green flashing) and negative energy (red flashing) to help troubleshoot connection problems, like swapped CTs, or excessive line voltage.

The output pulses from the WattNode meter can also be recorded using a data logger or other data acquisition device such as a building automation system. These systems can calculate the average kW demand during a sample interval and can also provide TOU (time of use) data. The pulse outputs of WattNode meters are optically isolated to provide 5000 volts protection from the AC power lines. An optocoupler functions like mechanical on/off switch. The pulse recording device connected to the meter applies a small DC voltage to the optocoupler switch to determine if it is open or closed. Each opening and closing of the switch represents one pulse.