CCS Products RWNC-3Y-400-BN
Wattnode BACnet Meter, 400 VAC Line to Line, Neutral, Revenue Model
CCS Products RWNC-3Y-400-BN
Wattnode BACnet Meter, 400 VAC Line to Line, Neutral, Revenue Model
- Communication protocol: BACnet MS/TP (RS-485)
- VAC line to line: 400
- VAC Line to Neutral: 230
- Communication protocol: BACnet MS/TP (RS-485)
- VAC line to line: 400
- VAC Line to Neutral: 230
- Meets ANSI C12.1 accuracy requirements when used with Accu-CT Class 0.6 current transformers
- Accuracy: 0.5% nominal
- Electrical service types: Single-Phase 230V with neutral, 3-Phase 4-Wire Wye 230/400V
- Line powered
- Operating Voltage Range: -20% to +15% of nominal
- Power Line Frequency: 50 or 60 Hz
- Pluggable screw terminals for easy wiring
- True RMS power even with leading or lagging power factor and chopped or distorted waveforms
- Measurements: True RMS Power: Watts (Phase A, B, C, and sum of all phases), Reactive Power: VARs (Phase A, B, C, and sum of all phases), Power Factor: (Phase A, B, C, and average of all phases), True RMS Energy: Kilo-Watthours kWh (Phase A, B, C, and sum of all phases), Reactive Energy: kVAR-hours (Phase A, B, C), AC Line Frequency, RMS Voltage: (Average and Phase A, B, C; line-to-line and line-to-neutral), Computed RMS Current: (Phase A, B, C), Demand, Peak Demand
- Measure variable speed motor drives used in HVAC, refrigeration, and pumping systems
The CCS Products RWNC-3Y-400-BN Wattnode BACnet Meter, 400 VAC Line to Line, Neutral, Revenue Model is a bidirectional networked energy meter offering energy measurement parameters such as energy (kW), power (kWh), voltage, current, demand, kVAR, kVARh, power factor, line frequency, etc. These energy values are communicated using the BACnet communication protocol over RS-485 as individual phase measurements and sum or average readings. The WattNode BACnet can be assigned MAC addresses from 0 to 63 using front panel DIP switches. Up to 64 WattNode BACnet meters can be daisy-chained on one RS-485 subnet.
Diagnostic LEDs provide a per-phase indication of power (green flashing) and negative power (red flashing) to help troubleshoot connection problems, like reversed CTs, or excessive line voltage. The WattNode BACnet meter also has a red/yellow/green communication LED to indicate traffic, configuration problems, bus contention and other conditions.
The WattNode BACnet's compact size permits installation inside most electrical service panels, junction boxes and OEM equipment. This model is line-powered, therefore does not require a separate powersource.
Brand | CCS Products |
---|---|
Condition | NEW |
Vendor Alias | RWNC-3Y-400-BN |
- 1 - Wattnode BACnet Meter