CCS Products WNC-3D-240-BN
Wattnode BacNET Meter, 208-240 VAC Line to Line, Standard
CCS Products WNC-3D-240-BN
Wattnode BacNET Meter, 208-240 VAC Line to Line, Standard
- VAC line to line: 208-240
- Electrical service types: Single-Phase 208V (No neutral), Single-Phase 240V (No neutral), Single-Phase 3-Wire 120/240V, 3-Phase 3-Wire Delta 208V-240V (No neutral), 3-Phase 4-Wire Wye 120/208V
- VAC line to line: 208-240
- Electrical service types: Single-Phase 208V (No neutral), Single-Phase 240V (No neutral), Single-Phase 3-Wire 120/240V, 3-Phase 3-Wire Delta 208V-240V (No neutral), 3-Phase 4-Wire Wye 120/208V
- Nominal accuracy 0.5%
- Measurements: True RMS Power: Watts (Phase A, B, C, and sum of all phases), Reactive Power: VARs (PhProtocol: BACnet MS/TP (RS-485), Baud Rates: 9600, 19200, 38400, and 76800 baudase A, B, C, and sum of all phases), Power Factor: (Phase A, B, C, and average of all phases), True RMS Energy: Kilo-Watthours kWh (Phase A, B, C, and sum of all phases), Reactive Energy: kVAR-hours (Phase A, B, C), AC Line Frequency, RMS Voltage: (Average and Phase A, B, C; line-to-line and line-to-neutral), Computed RMS Current: (Phase A, B, C), Demand, Peak Demand
- Line powered
- Operating Voltage Range: -20% to +15% of nominal
- Power Line Frequency: 50 or 60 Hz
- Pluggable screw terminals for easy wiring
- True RMS power even with leading or lagging power factor and chopped or distorted waveforms
- Measure variable speed motor drives used in HVAC, refrigeration, and pumping systems
The CCS Products WNC-3D-240-BN Wattnode BacNET Meter, 208-240 VAC Line to Line, Standard is a bidirectional networked energy meter offering energy measurement parameters such as energy (kW), power (kWh), voltage, current, demand, kVAR, kVARh, power factor, line frequency, etc. These energy values are communicated using the BACnet communication protocol over RS-485 as individual phase measurements and sum or average readings. The WattNode BACnet can be assigned MAC addresses from 0 to 63 using front panel DIP switches. Up to 64 WattNode BACnet meters can be daisy-chained on one RS-485 subnet.
The WattNode BACnet's compact size permits installation inside most electrical service panels, junction boxes and OEM equipment. The WattNode BACnet is line-powered, therefore does not require a separate powersource. Diagnostic LEDs help ensure fast and correct installation as well as network communication.
Brand | CCS Products |
---|---|
Condition | NEW |
Vendor Alias | WNC-3D-240-BN |
- 1 - Wattnode BacNET Meter