E-Mon E10561
PowerSmart Plus Socket Meter with Modbus RTU, 120V to 277V AC
E-Mon E10561
PowerSmart Plus Socket Meter with Modbus RTU, 120V to 277V AC
The E-Mon D-Mon E10561 PowerSmart Plus Socket Meter with Modbus RTU is an advanced power quality analyzer in a socket meter configuration. The device provides long term memory for load and trend profiles and includes advanced power quality analysis to detect and record waveform events and fault currents that are harmful to power systems.
- Modbus RTU
- High Range Measurement Input Nominal Rating: 120V AC to 277V AC (L-N)
- Modbus RTU
- High Range Measurement Input Nominal Rating: 120V AC to 277V AC (L-N)
- Certifications: UL/CSA 61010-1, ANSI C12.20, Class 10/20, IEC 62053-22, Class 0.25
- Precise Class 0.2 Active Energy/Power demand meter with easy-to-read 4 in. graphical display, multiple tariffs, Time Of Use (TOU), transformer, line losses, unique anti-tampering, self-test functions
- Form 9S configuration for new/retrofit socket-style installation
- High-quality power quality recorder with onboard PQ analyzer according to EN50160, programmable thresholds with hysteresis, ready-to-use reports, sags/swells, interruptions, frequency variations, flicker, temporary over-voltages, transient over-voltages, voltage unbalance, harmonic, interharmonic voltages
- Programmable controller with 32 control set points, OR/AND logic, extensive triggers, programmable thresholds/delays, relay control, event-driven data recording
- High-Class 3-phase demand power meter with amps, volts, harmonic demands, True-RMS of volts/amps, powers, power factors, neutral current
- Harmonic analyzer to 63th harmonic volts/amps, power harmonics, power factor, phasor, symmetrical components
- Event recorder for logging internal diagnostics events, control events, I/O operations
- Digital fault recorder with onboard fault detector-programmable fault, up to 50 Amps fault currents, zero-sequence currents/volts, current/volt unbalance, under-voltage, neutral current
- Uses flash memory for storing device firmware that allows future upgrading of device without replacing any hardware component
- New features can be easily added to device by simply replacing firmware through local RS-232/RS-485, USB, Ethernet port
- Non-volatile memory of 16 MB for energy/tariff registers logging, EV-PQ-WV log
- Four fast waveform recorders, selectable AC sampling rate of 32-1024 samples per cycle, 20 pre-fault cycles, 1-ms resolution for digital inputs monitoring, up to 3 min. of continuous recording with 8 MB onboard memory at rate of 32 samples per cycle
- Sixteen fast data recorders from 1/2 cycle RMS to 2 hour RMS envelopes, up to 20 pre-fault cycles, programmable data logs on periodic basis, on any internal/external trigger
- 16 programmable timers from 1/2 cycle to 24 hours for periodic recording/triggering operations on time basis
- Built-in digital optically isolated fast inputs, 1 KYZ relay output
The E-Mon D-Mon E10561 PowerSmart Plus Socket Meter with Modbus RTU is an advanced power quality analyzer in a socket meter configuration. The device provides long term memory for load and trend profiles and includes advanced power quality analysis to detect and record waveform events and fault currents that are harmful to power systems. The E10561 is ideal for government and large campus facilities, electric utility entities, or any electrical substation where precise energy information is required. Applications include power planning as well as monitoring primary customers at the service entrance to provide a higher service level of power quality.
The E10561 features a high range measurement input nominal rating of 120V AC to 277V AC (L-N). This model is supplied with the capability for Modbus RTU communication protocol.
Brand | E-Mon D-mon |
---|---|
Catalog | E-PS-S-SV-RTU |
Condition | NEW |
Vendor Alias | E10561 |
- 1 - PowerSmart Plus Socket Meter with Modbus RTU, 120V to 277V AC (E10561)