E-Mon E10581
(E-MPS-800-50-SPL) Split-Core Current Sensor, 800A, 1.9" X 3.1" Inner Diameter, One Piece
E10581
E10581
E-Mon E10581
(E-MPS-800-50-SPL) Split-Core Current Sensor, 800A, 1.9" X 3.1" Inner Diameter, One Piece
E10581
E10581
- Split-Core Sensor
- 800 Amp
- 1.9" X 3.1" Inner Diameter
- Split-Core Sensor
- 800 Amp
- 1.9" X 3.1" Inner Diameter
- For use with Multi-Mon & PowerSmart+ Meters
- E-Mon's patented 0-2V output split-core current sensors allow users to easily monitor energy usage in new or retrofit applications
- Sensors are sized according to the meter they are installed with and are sized to fit the typical wire size for that amperage
- E-Mon current sensors are installed inside the electrical panel and "snap" around the load wires to be monitored
- The sensors can monitor anything from a single branch circuit, to multiple circuits, to the entire building
- E-Mon current sensors can be installed up to 2,000 feet away from the meter (500 feet on Class 3x00 & Class 5000 meters) by extending the current sensor leads using #14-22 AWG wire (stranded/twisted not required)
- 3' leads are supplied from the factory, consult local electrical costs for proper wiring size requirements
- Current sensors can be installed around multiple load wires from the same source to provide a cumulative reading of usage for all of the loads
- Note: Phase correspondence is required, and all loads must be from the same voltage source/transformer
- Multiple sets of current sensors can be installed on one meter to provide a cumulative reading of multiple loads from different panels
- Up to 3 sets of sensors can be installed on one meter
- Note: Phase correspondence is required, all loads must be from the same voltage source/transformer, and all current sensors must be of the same amperage rating
- Current sensors can be used for subtractive metering: an example of subtractive metering is one set of current sensors installed around the main load wires in a panel; a second set of current sensors is installed around the load wires going to a subpanel, but the current sensors are reversed during installation -- this will provide a net reading of the total panel less the sub panel
- Note: Phase correspondence is required, all loads must be from the same voltage source/transformer, and all current sensors must be of the same amperage rating
- Optional solid-core current sensors are available in 100 & 200 amp configuration, specify when ordering
The EMon E10581 is a 800A Split Core Current Sensor with a 1.9" X 3.1" Inner Diameter. The E10581 works with the Multi-Mon and PowerSmart+ meters.