E-Mon E34-4003200-J-02-KIT

Class 3400 kWh Submeter, 400V, 3200A, JIC Steel Enclosure, Modbus RTU, EZ-7 Ethernet Protocol, 3 Split-Core Current Sensors w/ 2V Output

E344003200J02
E34-4003200-J-02-KIT

E-Mon E34-4003200-J-02-KIT

Class 3400 kWh Submeter, 400V, 3200A, JIC Steel Enclosure, Modbus RTU, EZ-7 Ethernet Protocol, 3 Split-Core Current Sensors w/ 2V Output

E344003200J02
E34-4003200-J-02-KIT
  • Brand Name: E-Mon D-mon
  • Condition: NEW
$2,326.31
This item ships FREE
  • Advanced 4-line display showing:
  • kWh
  • kW demand (with peak date & time)
  • Power factor per phase
  • Real-time load in kW
  • Amps per phase
  • Volts per phase
  • On-board set-up option for:
  • Meter date/time
  • IP address
  • Load control settings
  • ID codes for EZ7, Modbus and BACnet
  • RS-485 Protocol Options:
  • E-Mon Energy EZ7 (Standard)
  • Modbus RTU
  • BACnet MS/TP
  • Optional expanded feature package provides additional features:
  • Load control option for load control/shedding
  • Two external meter inputs -- water, gas, BTU, etc. -- stored in channels 5 & 6
  • Two Pulse outputs (one kWh and one kVARh)
  • 0-2 volt output split-core current sensors allow for enhanced safety and accurate remote mounting of sensors up to 500 feet from meter without power interruption (optional solid-core sensors available)
  • Onboard installation diagnostics and verification system
  • Built-in RS-485 communications capability supports the following connection configurations (or combinations not to exceed 52 devices per channel):
  • Up to 52 Class 3200, 3400 or 5000 meters and/or IDR interval data recorders
  • Cabling can be either daisy-chain or star configuration, 3-conductor, 18-22 AWG, up to 4,000 cable feet total per channel
  • Communications: Built-in communication
  • RS-485
  • Ethernet
  • Pulse output
  • Optional telephone modem
  • Protocols (*NOTE: Interval data not stored in BACnet or LonWorks units)
  • EZ7
  • BACnet MS/TP*
  • Modbus RTU
  • BACnet IP*
  • Modbus TCP/IP
  • LonWorks FT-10 (Twisted Pair)*
  • Records kWh & kVARh delivered, kWh & kVARh received in first four channels
  • Data stored in 15-min intervals for up to 72 days or 5-minute intervals for up to 24 days
  • Maintains interval data storage in a first-in, first-out format
  • Compatible with E-Mon Energy software via EZ7 protocol for automatic meter reading, billing and profiling of interval energy data
  • Meter is designed for use on both 3-phase, 3-wire (delta) and 3-phase, 4-wire (wye) circuits
  • Outdoor NEMA 4X polycarbonate enclosure (standard) with padlocking hasp & mounting flanges for indoor/outdoor installation (stand alone) with one 1 1/16" KO on bottom of enclosure
  • Optional industrial grade JIC steel enclosure w/padlocking hasp & mounting flanges for indoor installation with three 1 1/16" KO (3/4" conduit) on bottom of enclosure
  • UL/CUL Listed: Certified by independent test lab to ANSI C12.20 national accuracy standards (+/- 0.2% from 1% to 100% of rated load)
  • MV-90 Compatible (with EZ7 only)

The E-Mon D-Mon E34-4003200-J-02-KIT is a Class 3400 Meter, 400V, 3200A, JIC Steel Enclosure, Modbus RTU, EZ-7 Ethernet Protocol, 3 Split-Core Current Sensors with 2V Output.