E-Mon E34-600100-J-04-SP-KIT
Class 3400 kWh Submeter, 600V, 100A, JIC Steel, EZ-7, Modbus TCP/IP, Single / 2 Phase (2 Element), 2 Split-Core Sensors w/ 2V Output
E34600100J04SP
E34-600100-J-04-SP-KIT
E-Mon E34-600100-J-04-SP-KIT
Class 3400 kWh Submeter, 600V, 100A, JIC Steel, EZ-7, Modbus TCP/IP, Single / 2 Phase (2 Element), 2 Split-Core Sensors w/ 2V Output
E34600100J04SP
E34-600100-J-04-SP-KIT
- Brand Name: E-Mon D-mon
- Condition: NEW
- Advanced 4-line display showing:
- kWh
- kW demand (with peak date & time)
- Power factor per phase
- Real-time load in kW
- Amps per phase
- Volts per phase
- On-board set-up option for:
- Meter date/time
- IP address
- Load control settings
- ID codes for EZ7, Modbus and BACnet
- RS-485 Protocol Options:
- E-Mon Energy EZ7 (Standard)
- Modbus RTU
- BACnet MS/TP
- Optional expanded feature package provides additional features:
- Load control option for load control/shedding
- Two external meter inputs -- water, gas, BTU, etc. -- stored in channels 5 & 6
- Two Pulse outputs (one kWh and one kVARh)
- 0-2 volt output split-core current sensors allow for enhanced safety and accurate remote mounting of sensors up to 500 feet from meter without power interruption (optional solid-core sensors available)
- Onboard installation diagnostics and verification system
- Built-in RS-485 communications capability supports the following connection configurations (or combinations not to exceed 52 devices per channel):
- Up to 52 Class 3200, 3400 or 5000 meters and/or IDR interval data recorders
- Cabling can be either daisy-chain or star configuration, 3-conductor, 18-22 AWG, up to 4,000 cable feet total per channel
- Communications: Built-in communication
- RS-485
- Ethernet
- Pulse output
- Optional telephone modem
- Protocols (*NOTE: Interval data not stored in BACnet or LonWorks units)
- EZ7
- BACnet MS/TP*
- Modbus RTU
- BACnet IP*
- Modbus TCP/IP
- LonWorks FT-10 (Twisted Pair)*
- Records kWh & kVARh delivered, kWh & kVARh received in first four channels
- Data stored in 15-min intervals for up to 72 days or 5-minute intervals for up to 24 days
- Maintains interval data storage in a first-in, first-out format
- Compatible with E-Mon Energy software via EZ7 protocol for automatic meter reading, billing and profiling of interval energy data
- Meter is designed for use on both 3-phase, 3-wire (delta) and 3-phase, 4-wire (wye) circuits
- Outdoor NEMA 4X polycarbonate enclosure (standard) with padlocking hasp & mounting flanges for indoor/outdoor installation (stand alone) with one 1 1/16" KO on bottom of enclosure
- Optional industrial grade JIC steel enclosure w/padlocking hasp & mounting flanges for indoor installation with three 1 1/16" KO (3/4" conduit) on bottom of enclosure
- UL/CUL Listed: Certified by independent test lab to ANSI C12.20 national accuracy standards (+/- 0.2% from 1% to 100% of rated load)
- MV-90 Compatible (with EZ7 only)
The E-Mon D-Mon E34-600100-J-04-SP-KIT is a Class 3400 Meter, 600V, 100A, JIC Steel Enclosure, EZ-7, Modbus TCP/IP Protocol, Single Phase or Two Phase (Two Element), 2 Split-Core Current Sensors with 2V Output.
Brand | E-Mon D-mon |
---|---|
Condition | NEW |