- Brand Name: E-Mon D-mon
- Condition: NEW
- Advanced 4-line display showing:
- kWh
- kW demand (with peak date & time)
- Power factor per phase
- Real-time load in kW
- Amps per phase
- Volts per phase
- On-board set-up option for:
- Meter date/time
- IP address
- ID codes for EZ7, Modbus and BACnet
- 0-2 volt output split-core current sensors allow for enhanced safety and accurate remote mounting of sensors up to 500 feet from meter without power interruption (optional solid-core current sensors available in 100 & 200 A)
- Onboard installation diagnostics and verification system
- Two external meter inputs -- water, gas, BTU, etc. -- channels 5 & 6 available via E-Mon Energy only
- Phase loss alarm (N.O. contact)
- Built-in RS-485 communications capability supports the following connection configurations (or combinations not to exceed 52 devices per channel):
- Up to 52 Class 3200, Class 3400 or 5000 meters and/or IDR interval data recorders
- Cabling can be either daisy-chain or star configuration, 3-conductor, 18-22 AWG, up to 4,000 cable feet total per channel
- Communications: Built-in communication
- RS-485 and Ethernet
- Optional telephone modem
- Protocols (*NOTE: Interval data not stored in BACnet or LonWorks units)
- EZ7
- Modbus RTU
- Modbus TCP/IP
- BACnet MS/TP*
- BACnet IP*
- LonWorks FT-10 (Twisted Pair)*
- Records kWh & kVARh delivered, kWh & kVARh received in first four channels
- Data stored in 15-min intervals for up to 72 days or 5-minute intervals for up to 24 days
- Maintains interval data storage in a first-in, first-out format
- Compatible with E-Mon Energy software via EZ7 protocol for automatic meter reading, billing and profiling of interval energy data
- Meter is designed for use on both 3-phase, 3-wire (delta) and 3-phase, 4-wire (wye) circuits
- Outdoor NEMA 4X polycarbonate enclosure (standard) with padlocking hasp & mounting flanges for indoor/outdoor installation (stand alone) with one 1 1/16" KO on bottom of enclosure
- Optional Enclosure: Industrial grade JIC steel enclosure with padlocking hasp and mounting flanges for indoor installation (stand alone)
- Knockouts: 1 1/16" (3/4" cond.) on bottom and 7/8" (1/2" cond.) on top of enclosure
- UL/CUL Listed Certified by independent test lab to ANSI C12.20 national accuracy standards (+/- 0.2% from 1% to 100% of rated load)
- MV-90 Compatible (with EZ7 only)
The E-Mon D-Mon E50-208100-R-06-SP-SCS is a Class 5000 Meter, 208V, 100A, NEMA 4X Enclosure, Modbus RTU, Modbus TCP/IP Protocol, Single Phase or Two Phase (Two Element), 2 Solid-Core Current Sensors with 2V Output.
The E-Mon D-Mon Class 5000 Three-Phase Advanced kWh/Demand Smart Meters with Dual Protocol Communication is a 3-phase meter with communications. The device is used to monitor electric power usage of individual loads after the utility meter and store kW and kVAR data for automatic meter reading. The E-Mon D-Mon Class 5000 Three-Phase Advanced kWh/Demand Smart Meters is dual protocol capable and provides both RS485 and Ethernet communications. Installation must only be performed by qualified personnel and in accordance with these instructions and all applicable local and national electrical codes.
E-Mon D-Mon Class 5000 Three-Phase Advanced kWh/Demand Smart Meters with Dual Protocol Communication are labeled for 120/208V service MUST NOT be installed on service feeds of 277/480 volts or 347/600 and vice versa. Verify that the E-mon Class 5000 meter's current sensors are sized suitably for the load to be monitored.
Brand | E-Mon D-mon |
---|---|
Condition | NEW |