E-Mon E50-600400-R-03-N-SP-KIT
Class 5000 kWh Submeter, 600V, 400A, NEMA 4X, BACnet MS/TP, EZ-7 Ethernet, Green Net Meter 1 Phase, 2 Split-Core Sensors w/ 2V Out
E-Mon E50-600400-R-03-N-SP-KIT
Class 5000 kWh Submeter, 600V, 400A, NEMA 4X, BACnet MS/TP, EZ-7 Ethernet, Green Net Meter 1 Phase, 2 Split-Core Sensors w/ 2V Out
- Brand Name: E-Mon D-mon
- Condition: NEW
- Advanced 4-line display showing:
- - kWh delivered, received and Net kWh
- - kWh/Demand (with peak date and time)
- - Power factor per Phase
- - Real-time load in kW
- - Amps per Phase
- - Volts per Phase
- On-board set-up option for:
- - IP Address
- - Meter date/time
- - ID codes for EZ7, Modbus and BACnet
- 0-2 volt output split-core current sensors allow for enhanced safety and accurate remote mounting of sensors up to 500 feet from meter without power interruption (optional solid-core current sensors available in 100 & 200 amp)
- Onboard diagnostics and verification system
- Two external meter inputs (water, gas, BTU, etc.), channels 5 & 6
- Phase loss alarm (N.O. Contact)
- Built-in RS-485 communications capability supports up to 52 Class 3200, 3400, 5000 meters and/or IDR interval recorders (or combinations not to exceed 52 devices per channel)
- Cabling can be either daisy-chain or star configuration, 3-conductor, 18-22 AWG, up to 4,000 feet cable total per channel
- Communications include built-in RS-485 & Ethernet and optional telephone modem
- Protocols
- - EZ7
- - Modbus RTU
- - Modbus TCP/IP
- - BACnet MS/TP*
- - BACnet IP*
- - LonWorks FT-10 (Twisted Pair)*
- Records kWh and kVARh delivered, kWh and kVARh received in first 4 channels; data stored in 15-minute intervals for up to 72 days or 5-minute intervals for up to 24 days; maintains interval data storage in a first-in, first-out format
- Compatible with E-Mon Energy software via EZ7 protocol for automatic meter reading, billing and profiling of interval energy data
- Meter is designed for use on both 3-phase, 3-wire (delta) and 3-phase, 4-wire (wye) circuits; optional single-phase 3-wire configuration available
- Industrial grade green JIC steel enclosure with padlocking hasp and mounting flanges for indoor installation (stand alone); knockouts: 1 1/16" (3/4" cond.) on bottom and 7/8" (1/2" cond.) on top of enclosure
- Optional outdoor NEMA 4X polycarbonate enclosure (standard) with padlocking hasp & mounting flanges for indoor/outdoor installation (stand alone) with one 1 1/16" KO on bottom of enclosure
- UL/CUL Listed: Certified by independent test lab to ANSI C12.20 national accuracy standards (+/- 0.2% from 1% to 100% of rated load)
- CE Mark approved
- Meter meets or exceeds MID accuracy standards
- BACnet protocol is BTL certified, LonWorks protocol is LonMark Certified
- MV-90 Compatible (EZ7 only)
The E-Mon D-Mon E50-600400-R-03-N-SP-KIT is a Class 5000 Meter, 600V, 400A, NEMA 4X Enclosure, BACnet MS/TP, EZ-7 Ethernet Protocol, Green Class Net Meter - Single Phase, 2 Split-Core Current Sensors with 2V Output.
The E-Mon D-Mon Class 5000 Three-Phase Advanced kWh/Demand Smart Meters with Dual Protocol Communication is a 3-phase meter with communications. The device is used to monitor electric power usage of individual loads after the utility meter and store kW and kVAR data for automatic meter reading. The E-Mon D-Mon Class 5000 Three-Phase Advanced kWh/Demand Smart Meters is dual protocol capable and provides both RS485 and Ethernet communications. Installation must only be performed by qualified personnel and in accordance with these instructions and all applicable local and national electrical codes.
E-Mon D-Mon Class 5000 Three-Phase Advanced kWh/Demand Smart Meters with Dual Protocol Communication are labeled for 120/208V service MUST NOT be installed on service feeds of 277/480 volts or 347/600 and vice versa. Verify that the E-mon Class 5000 meter's current sensors are sized suitably for the load to be monitored.
Brand | E-Mon D-mon |
---|---|
Condition | NEW |