Elektro-Automatik PS 10500-10 2U

Single Output Programmable DC Laboratory Power Supply, 500V/10A, 1500W, 2U Rack

EAPS10500102U
PS 10500-10 2U

Elektro-Automatik PS 10500-10 2U

Single Output Programmable DC Laboratory Power Supply, 500V/10A, 1500W, 2U Rack

EAPS10500102U
PS 10500-10 2U

The Elektro-Automatik PS 10500-10 2U Single Output Programmable DC Power Supply converts energy from a grid into a regulated DC voltage. It also operates as a flexible output stage with a constant power characteristic (auto-ranging).

  • Power: 1500 W
  • Voltage: 500 V
  • Current: 10 A
  • Standard interfaces: USB/Ethernet/Analog/USB Host/Master-Slave-Bus/Share-Bus
  • Optional interfaces: CAN/CANopen/RS232/Profibus/EtherCAT/Profinet/Modbus
  • Output power rating: 0 to 1500 W
  • Output voltage: 0 to 500 V
  • Output current: 0 to 10 A
  • Number of outputs: One
  • Efficiency: 95%
  • Programmable DC Laboratory Power Supply
  • Wide range input: 110 to 240 V, +10 %, 1ph AC
  • Active Power-Factor-Correction, typical 0.99
  • Flexible power regulated DC output stages (auto-ranging)
  • Protective functions: OCP, OPP, OTP, OVP
  • Regulation modes: CV, CC, CP with fast crossover
  • Rack housing: 19 in. x 2U
  • Digital regulation, high resolution with 16-bit ADC's and DAC's, selection of control speed: Normal, Fast, Slow
  • 5 in. Color TFT display with touch control and intuitive user interface
  • Master-Slave bus for parallel operation of up to 64 units for all power classes in 1000 Series Power Supplies
  • Command languages and drivers: SCPI and ModBus, LabVIEW, IVI
  • Standard interfaces: USB, Ethernet, Analog, USB Host, Master-Slave-Bus, Share-Bus
  • Optional interfaces (not included): CAN, CANopen, RS232, Profibus, EtherCAT, Profinet (with one or two ports), Modbus (with one or two ports), Ethernet (with one or two ports)

The Elektro-Automatik PS 10500-10 2U Single Output Programmable DC Power Supply, 500V/10A, 1500W, 2U Rack converts the energy from the grid into a regulated DC voltage with an efficiency of over 96%. The DC supply operates as a flexible output stage with a constant power characteristic (auto-ranging) and a wide voltage, current and power range. To achieve higher power and current this unit is equipped with a master-slave bus. This enables up to 64 parallel connected devices to be combined into one system. Such a system works as a single unit and can use different power classes, only the voltage class must remain constant. Furthermore, typical laboratory functionality is provided.

The EA-PS 10500-10 2U is equipped with an active PFC which provides a high efficiency at a low energy consumption, while providing a wide input voltage range. This devices can be operated in the majority of global grids. It adjust automatically, without additional configuration, to the available grid voltage.

Connection of the DC output is done via copper blades on the back side of the PS 10500-10 2U. With minimal effort these devices can be linked with the vertical copper rails; a cover is included to protect the contact.

As standard, the PS 10500-10 2U is fitted with the most important interfaces and ports which are all galvanically isolated from the DC input. There is an analog interface which can be parameterized for input and output, control and monitoring, voltage, current, power and resistance, assorted inputs and outputs, as well as USB and Ethernet ports.

When the integrated master-slave bus and share bus are used, a multi device system behaves as a single device. The buses are simply connected between each device. With the master-slave bus, the system data (such as total power and total current) are collected and displayed on the master unit (PS 10500-10 2U). Warnings and alarms of the slave devices (not included) will also clearly display on the master unit (PS 10500-10 2U).

Relay manufacturers must carry out assorted tests on their products during production. For these the coils and contacts are provided with exactly defined voltage and current. For the coil tests, important parameters such as operating, holding and decay current - together with the associated voltages - must be checked and documented. For the contacts, not only are the current carrying capability and contact resistance important parameters, but also voltage consistency and disconnect threshold indicate much about the product quality. Testing all of these is best supported by an automatic test system. A PS 10500-10 2U can be a part of such a system with its exact, dynamic controls of voltage, current, power, and resistance, providing optimal values for the best test results. With its diverse interface connections, the PS 10500-10 2U can be integrated into any test system and deliver the necessary data without the need for additional measuring equipment.

During an on-board charger test (OBC), the electrical features must be tested under various conditions. This requires a flexible test system which also provides test data. With the sequencing and logging functions of the PS 10500-10 2U test procedures allow data to be read out and saved. In this way, applications can promptly generate reproducible test results based on dynamic and highly accurate set point and measurement data. To avoid competition between two separate control loops of the device under test (DUT) and testing device, the voltage regulation speed of PS 10500-10 2U bidirectional power supply is adjustable. The modes Normal/Fast/Slow allow the power supply to adapt to the control characteristics of the on-board charger.

More Information
BrandElectro-Automatik
ConditionNEW
  • 1 - Single Output Programmable DC Laboratory Power Supply, 500V/10A, 1500W, 2U Rack (PS 10500-10 2U)
  • 2 - Remote Sensing Plugs
  • 1 - USB Cable, 1.8 m
  • 1 - Set of DC Terminal Covers
  • 1 - Sense Terminal Cover
  • 1 - Cable Tie for Strain Relief
  • 1 - Documentation and Software