Fluke Calibration 1502A-156
Tweener Thermometer Readout for RTD, RTD and SPRT Probes
Fluke Calibration 1502A-156
Tweener Thermometer Readout for RTD, RTD and SPRT Probes
- Temperature range: -200 °C to 962 °C (-328 °F to 1764 °F)
- Resistance range: 0Ohm to 400 Ohm, auto-ranging
- Probe: Nominal RTPW: 10Ohm to 100Ohm RTD, PRT, or SPRT
- Temperature range: -200 °C to 962 °C (-328 °F to 1764 °F)
- Resistance range: 0Ohm to 400 Ohm, auto-ranging
- Probe: Nominal RTPW: 10Ohm to 100Ohm RTD, PRT, or SPRT
- Resistance accuracy (ppm of reading): 0Ohm to 20Ohm: 0.0005Ohm; 20Ohm to 400Ohm: 25 ppm
- Temperature accuracy: ±0.004 °C at -100 °Cl ±0.006 °C at 0 °C; ±0.009 °C at 100 °C; ±0.012 °C at 200 °C; ±0.018 °C at 400 °C; ±0.024 °C at 600 °C
The Fluke Calibration 1502A156 Tweener Thermometer Readout for RTD, RTD and SPRT Probes features accuracy up to ±0.006 °C. In addition, it reads 100-ohm, 25-ohm, and 10-ohm probes, and has a resolution of 0.001 °C across its entire range. It also has an optional battery pack for completely portable operation.
Each Tweener is programmable to match a probe's constants for maximum linearity and accuracy. All probe constants and coefficients are programmed through simple, front-panel keystrokes. Temperature is displayed in °C, °F, K, or resistance in ohms.
The Fluke Calibration 1502A-156 accurately measures the resistance of the probe and then converts the resistance into a temperature value, using its built-in algorithms.
For convenience, the 1502A-156 reads the common industrial grade IEC-751 or "385" ALPHA RTD without any programming. Enter the actual R0 and ALPHA of the individual probe for increased accuracy. For maximum accuracy, use the ITS-90 formulas. The 1502A-156 accepts the subranges 4 and 6 through 11.
ITS-90 formulas reside in the Tweener's firmware. If your probe has been calibrated for any of the above subranges of the ITS-90, you simply enter the coefficients directly into the 1502A-156 unit.
The 1502A-156 comes complete with an RS-232 interface for automation of temperature data collection, calibrations, or process control functions. An IEEE-488 interface is also an available option.
The Fluke Calibration 1502A-156 is calibrated digitally using the front-panel buttons. You never have to open the box to calibrate it. This calibration protocol further reduces the cost of this unit; it goes where you go and works the way that you want it to.
Country of Origin | United States |
---|---|
Brand | Fluke Calibration |
Condition | NEW |
- 1 - Extra Probe Connector
- 1 - Power Cord
- 1 - User Manual