Fluke Calibration 5610-9-P
Thermistor Probe with INFO-CON for 1523/1524, 9 in. x 1/8 in., 0 °C to 100 °C, 6 ft. Lead
Fluke Calibration 5610-9-P
Thermistor Probe with INFO-CON for 1523/1524, 9 in. x 1/8 in., 0 °C to 100 °C, 6 ft. Lead
- Brand Name: Fluke Calibration
- Condition: NEW
- Country of Origin: United States
- Termination: INFO-CON for Models 1523 and 1524
- Nominal 10,000 Ohm at 25 °C
- Range: 0 °C to 100 °C
- Size: 9 in. x 1/8 in.
- 6 ft. Lead
- Calibration: R vs. T table with 0.1 °C increments, interpolation equation furnished
- Calibration Uncertainty: Table and equation are accurate to ± 0.01 °C
- Optional accredited (NVLAP Lab Code 200348-0) calibration uncertainties: ± 0.006 °C
- Drift: Better than ± 0.01 °C per year (k=3)
- Repeatability: Better than ± 0.005 °C
The Fluke Calibration 56109P Thermistor Probe with INFO-CON for 1523/1524, 9 in. x 1/8 in., 0 °C to 100 °C, 6 ft. Lead stainless steel metal-sheath probe is great for measuring in air, liquid or soil.
Higher performance
The Fluke Calibration 5610-9-P not only has a small diameter, but a very small sensing element, which means it requires far less immersion than a PRT to avoid errors caused by stem effect. Self heating is usually negligible, giving it an advantage when taking measurements in air. Its small size also improves response time, allowing measurements to be taken more quickly.
If your application involves frequent handling, you will be especially interested to know thermistors are less susceptible to mechanical shock than PRTs. The bottom line may be better accuracy in fieldwork.
Additionally, higher base resistance and larger resistance coefficients make it easier to achieve precision readings with this thermistor; it has a negative temperature coefficient of resistance (NTC).
Readouts
This probe comes in a complete assembly ready for use, and each works well with the uncertainties of Fluke Calibration thermometer readouts: the 1504 Tweener, the 1523 and 1524 Handheld Thermometers, the 1529 Chub-E4, the 1560 Black Stack, and the 1575A and 1590 Super-Thermometers. The 5610-9-P provides the most accurate readings when coupled with a 2563 Standards Thermistor Module or 1590 Super-Thermometer, but most portable when used with a handheld reference thermometer.
Calibrated Accuracy
What's more, the Fluke Calibration 5610-9-P is accurate to ± 0.01 °C and covers the temperature range of 0 °C to 100 °C. It comes with a NIST-traceable calibration and a resistance-versus-temperature table printed in 0.1 °C increments that can be interpolated to 0.0001 °C. NVLAP accredited calibrations as single thermistors or as systems combined with their readouts, are also available.
Country of Origin | United States |
---|---|
Brand | Fluke Calibration |
Condition | NEW |
- 1 - Coefficient Sheet
- 1 - User Manual CD