Fluke Calibration 5618B-6-P

Small Diameter Industrial RTD Probe with INFO-CON for 1523/1524, 6 in. x 1/8 in., 6 ft. Lead

5618B6P
5618B-6-P

Fluke Calibration 5618B-6-P

Small Diameter Industrial RTD Probe with INFO-CON for 1523/1524, 6 in. x 1/8 in., 6 ft. Lead

5618B6P
5618B-6-P
  • Brand Name: Fluke Calibration
  • Condition: NEW
  • Country of Origin: United States
This product is available for shipping to the US, Canada, and Puerto Rico only.
$1,493.95 Price $1,660.00
This item ships FREE
  • Termination: INFO-CON for Models 1523 and 1524
  • Resistance: Nominal 100 Ohm at 0 °C
  • Temperature coefficient: 0.003923 Ohm/Ohm/°C nominal
  • Temperature range: -200 °C to 300 °C
  • Drift Rate: ±0.1 °C when used periodically to 500 °C
  • Sheath Material: 316 SST
  • Leads: 22 AWG PTFE, 6 ft.
  • Hysteresis: Less than 0.01 °C at 0 °C when using -196 °C and 420 °C as end points
  • Time constant: Four seconds maximum for 63.2% response to step change in water moving at 3 fps.
  • Thermal EMF: Less than 25 mV at 420 °C
  • Calibration: Includes manufacturer's NVLAP-accredited calibration w/ITS-90 coefficients, R vs. T values in 1 °C increments, lab code 200706-0
  • Size: 152 mm L x 3.2 mm dia. (6 in. x 1/8 in.)
  • Calibrated accuracy (Includes calibration uncertainty and drift specification) (k=2): ±0.026 °C at -200 °C; ±0.066 °C at 0 °C; ±0.219 °C at 500 °C

The Fluke Calibration 5618B6P Small Diameter Industrial RTD Probe with INFO-CON for 1523/1524, 6 in. x 1/8 in., 6 ft. Lead is an excellent choice for secondary level performance with full ITS-90 calibration and critical temperature measurements. Featuring a 3.2 mm diameter (1/8 in.) sheath, this industrial standards probe has reduced response time without compromising precision. This small diameter probe works well in many applications where immersion depth is limited. Larger diameter probes give more measurement error in short immersion depth applications because they conduct more heat between ambient and the sensor.

With the 5618B-6-P you will receive full NVLAP-accredited calibration report. On the report you will get the test data and the ITS-90 calibration coefficients that you can easily input into your Fluke Calibration thermometer.

The 5618B-6-P is also a great probe to use for calibrating your Fluke Calibration 9132 or 9133 infrared calibrators. In fact, these IR black body heat sources were designed to be calibrated with this type of probe.

For use from -200 °C to 300 °C, you will not find a better industrial standard in this configuration than the Fluke Calibration 5618B-6-P.

More Information
Country of OriginUnited States
BrandFluke Calibration
ConditionNEW
  • 1 - Coefficient Sheet
  • 1 - User Manual CD
  • 1 - Certification Sheets