Fluke Calibration 5623B-6-M

Precision RTD Freezer Probe with Mini Banana Plugs, 6 in. x 1/4 in., -100 °C to 156 °C

5623B6M
5623B-6-M

Fluke Calibration 5623B-6-M

Precision RTD Freezer Probe with Mini Banana Plugs, 6 in. x 1/4 in., -100 °C to 156 °C

5623B6M
5623B-6-M
  • Termination: Mini banana plugs
  • Resistance nominal 100 Ohm (±0.1 Ohm)
  • Temperature coefficient: 0.003925 Ohm/Ohm/°C nominal
This product is available for shipping to the US, Canada, and Puerto Rico only.
$1,318.45 Price $1,416.00
This item ships FREE
  • Termination: Mini banana plugs
  • Resistance nominal 100 Ohm (±0.1 Ohm)
  • Temperature coefficient: 0.003925 Ohm/Ohm/°C nominal
  • Temperature range: -100 °C to 156 °C
  • Transition temperature: -100 °C to 156 °C
  • Drift rate: ±0.01 °C per year maximum at 0 °C, when used periodically at max temperature
  • Sheath material: Inconel 600
  • Leads: PTFE-insulated, silver-plated stranded copper, 22 AWG
  • Calibration: Includes manufacturer's NVLAP-accredited, lab code 200706-0, calibration and table with R vs. T values in 1 °C increments from -80 °C to 156 °C (ITS-90 coefficients included)
  • Calibrated accuracy (Includes calibration uncertainty and drift) (k=2): ±0.05 °C over the full range
  • Cable length: 6.1 meters (20 ft)
  • Size: 6.35 mm (0.25 in.) dia. x 152 mm (6 in.)

The Fluke Calibration 5623B6M Precision RTD Freezer Probe with Mini Banana Plugs, 6 in. x 1/4 in., -100 °C to 156 °C is specially sealed from the sensing element to the end of the probe cable, preventing ingress of moisture when exposed to temperatures as low as -100 °C. The entire assembly withstands temperatures over its full range (-100 °C to 156 °C), which is ideal for verification of freezers or autoclaves where a thermo-well is not available. The 5623B-6-M assembly can be fully immersed in fluids when the application may require use in a liquid bath. With an accuracy (including calibration uncertainty and short-term drift) of ± 0.05 °C over its full range, the 5623B-6-M is perfect as a secondary standard for calibration of other process sensors.

With each 5623B-6-M, you receive a full NVLAP-accredited calibration report. This report includes test data and ITS-90 calibration coefficients to enter into your Fluke Calibration thermometer readout.

Most Fluke Calibration readouts make an excellent companion for the 5623B-6-M, including the 1523, 1524, 1502A, 1529, or 1560 thermometer readouts.

More Information
Country of OriginUnited States
BrandFluke Calibration
ConditionNEW
  • 1 - Coefficient Sheet
  • 1 - User Manual CD
  • 1 - Certification Sheets