Fluke Calibration 5627A-9-L

Precision Industrial RTD Probe with Mini Spade Lugs, 9 in. x 3/16 in., -200 °C to 300 °C

5627A9L
5627A-9-L

Fluke Calibration 5627A-9-L

Precision Industrial RTD Probe with Mini Spade Lugs, 9 in. x 3/16 in., -200 °C to 300 °C

5627A9L
5627A-9-L
  • Brand Name: Fluke Calibration
  • Condition: NEW
  • Country of Origin: United States
This product is available for shipping to the US, Canada, and Puerto Rico only.
$1,060.95 Price $1,193.00
This item ships FREE
  • Termination: Mini spade lugs
  • Resistance: Nominal 100 Ohm
  • Temperature coefficient: 0.00385 Ohm/Ohm/°C nominal
  • Temperature range: -200 °C to 300 °C (transition and cable temperature: 0 °C to 150 °C)
  • Drift rate (k=2): ±0.04 °C at 0 °C after 100 hours at 420 °C
  • Sheath material: 316 stainless steel
  • Leads: PTFE-insulated, nickel-plated stranded copper, 22 AWG
  • Time constant: Four seconds maximum for 63.2% response to step change in water moving at 3 fps
  • Bending radius: Sheath may be ordered with a bend on minimum radius of 19 mm (3/4 in.) except for 50 mm (2 in.) area of sheath near tip
  • Calibration: Includes manufacturer's NVLAP-accredited (lab code 200706-0) calibration and table with R vs; T values in 1 °C increments from -196 °C to 300 °C; ITS-90 coefficients included
  • Immersion: At least 100 mm (4 in.) recommended
  • Calibrated accuracy (includes calibration uncertainty and 100 hr drift) (k=2): ±0.026 °C at -196 °C; ± 0.046 °C at 0 °C; ±0.077 °C at 200 °C; ±0.124 °C at 420 °C
  • Size: 229 mm x 4.7 mm (9 in. x 3/16 in.)

The Fluke Calibration 5627A9L Precision Industrial RTD Probe with Mini Spade Lugs, 9 in. x 3/16 in., -200 °C to 300 °C has a temperature range of up to 300 °C and an accuracy as good as ± 0.025 °C. This precision thermometer is shipped with its ITS-90 coefficients and a calibration table in 1 °C increments. One of the best features of the 5627A-9-L sensor is that it conforms to the standard 385 curve, letting you use your DIN/IEC RTD meters fully.

The 5627A-9-L is manufactured using a coil suspension element design for increased shock and vibration resistance. It has a mineral-insulated sheath with a minimum bend radius of 19 mm (3/4-inch) for flexibility and durability. It is individually calibrated and includes a NVLAP-accredited report of calibration from the manufacturer with lab code 200706-0.

More Information
Country of OriginUnited States
BrandFluke Calibration
ConditionNEW
  • 1 - Coefficient Sheet
  • 1 - User Manual CD
  • 1 - Certification Sheets