Fluke PVA-1500T2
Solmetric PV Analyzer I-V Curve Tracer
The Fluke PVA-1500T2 is a Solmetric PV Analyzer I-V Curve Tracer that is designed for testing and analyzing individual solar photovoltaic (PV) modules. With advanced features and precision measurement capabilities, the PVA-1500T2 offers comprehensive data analysis and reporting features.
- Detect issues such as shading, mismatch, degradation, and other performance anomalies
- Sweep-to-sweep delay of 9 seconds
- User-friendly interface with wireless connectivity
- Advanced built-in PV model provides immediate PV performance checking
- Reliably assess health/performance of PV system solar modules/arrays
- High throughput I-V curve tracing
- Intuitive user interface for easy navigation
- Real-time analysis for immediate identification of potential issues
- Aids in maximizing solar energy production, minimizing downtime
- I-V curve testing offers complete solar module performance measurement
- Curve datasets aid in detecting outliers, stored data acts as baseline for future inquiries
- Measures, displays I-V of PV string/module via capacitive load up to 1500V/30A
- Generates P-V curve, Isc, Voc, Imp, Vmp, Pmax, fill factor, performance factor
- Wireless interfaces for faster setup, safer work environment, freedom of movement during PV troubleshooting
- SolSensor provides irradiance, module temperature, array tilt data to main unit
- Predicts I-V curve shape at operating conditions, translates measured curve to standard test conditions
- Spectral response of silicon photodiode sensor within SolSensor is corrected for PV technology under test
- Accurate over broad range of technologies, sky conditions, sun angles
- Two external thermocouple inputs for measuring module backside temperatures
- Data Analysis Tool (DAT) presents analysis results in multiple formats
- DAT compiles key PV parameters in string table, flags non-conforming strings, delivers statistical overview of entire array
- Automates data management, analysis, reporting
- Database of more than 70,000 modules with automatic updates
- In-the-field firmware update ready
- Commissioning
- Operations
- Maintenance
- Auditing
- Troubleshooting
- Voltage Range (Voc): 20 to 1500V DC
- Maximum Current Range (Module Efficiency less than 19%): 0 to 30A DC
- Maximum Current Range (Module Efficiency more than/equal to 19%): 0 to 10A DC
- Voltage Accuracy: +/-(0.5% + 0.25V)
- Current Accuracy: +/-(0.5% + 0.04A)
- Power Accuracy: +/-(1.7% + 1.0W)
- Voltage Resolution: 25 mV
- Current Resolution: 2 mA
- I-V Trace Points: 100 or 500 (selectable)
- I-V Sweep Duration: 0.05 to 2 seconds (typically 0.2 seconds for PV strings)
- Operating Temperature (Ambient): 0°C to 45°C (32°F to 113°F)
- Sweep-to-Sweep Delay: Less than 9 seconds
- Maximum Number of I-V Sweeps per Hour: 400 sweeps/hour
- Maximum Megawatts Measured per Hour: 3.5 MW/hour
The Fluke PVA-1500T2 Solmetric PV Analyzer I-V Curve Tracer is a cutting-edge I-V curve tracer designed to measure photovoltaic (PV) system performance. With this high-precision testing equipment, the user can reliably assess the health and performance of solar modules and arrays. Easily being able to determine the health of these units allows for informed decisions to be made in order to enhance their output and longevity.
The Fluke Solmetric PVA-1500T2 offers an array of advanced features. The high throughput I-V curve tracing provides quick and detailed performance data. The intuitive user interface enables easy navigation and real-time analysis which allows for immediate identification of potential issues. By pinpointing problems early, the user can maximize solar energy production and minimize downtime.
Comprehensive Measurements and Efficient AnalysisI-V curve testing is the most complete solar module performance measurement for commissioning, operations, maintenance, and troubleshooting of PV arrays. Quick analysis of curve datasets aids in detecting outliers. The stored data functions as a baseline for future performance inquiries.
Accurate I-V Curve TracingThe Fluke Solmetric PVA-1500T2 measures the I-V (current versus voltage) curve of a PV string or module using a capacitive load. The measurement is typically performed at the string level by connecting directly to the string or at a combiner box using the fuses to select the string under test. The number of I-V curve points can be selected at 100 or 500. Additionally, the Fluke Solmetric PVA-1500T2 generates the P-V (power versus voltage) curve, Isc, Voc, Imp, Vmp, Pmax, fill factor, and performance factor which is the ratio of measured to expected maximum power.
Time-Saving InterfaceWith a tablet or laptop (Windows only) as the user interface, the user can perform more tests per hour and display the data in multiple easy-to-read formats.
By touching the customized array tree at the branch being measured, the user can save their measurements. The software automatically calculates the expected I-V curve and displays the performance factor.
SolSensor Wireless PV Reference SensorThe SolSensor provides irradiance, module temperature, and array tilt data to the Fluke Solmetric PVA-1500T2 model. The unit uses this information to predict the I-V curve shape at these operating conditions and to translate the measured curve to standard test conditions. The SolSensor clamps to the module frame and automatically orients the irradiance sensor to the plane-of-array.
Irradiance and Temperature AccuracyThe spectral response of the silicon photodiode sensor in the SolSensor is corrected for the PV technology under test. Special factors are provided for multi- and mono-crystalline cells as well as cadmium telluride (CdTe) and other thin film technologies. The sensor is temperature compensated and the angular response of each unit is calibrated for rotation and elevation. As a result, the SolSensor is accurate over a broad range of technologies, sky conditions, and sun angles. The high accuracy across the board allows for I-V curve measurements both earlier and later in the day.
The SolSensor provides two external thermocouple inputs for measuring module backside temperatures. Effective cell temperature can also be calculated directly from the measured I-V curve per IEC 60904-5. The Fluke Solmetric PVA-1500T2's SmartTemp feature blends these two methods for best accuracy.
Wireless ConnectivityWireless interface between the user’s tablet or laptop (Windows), Fluke Solmetric PVA-1500T2, and SolSensor is possible.
The unit and SolSensor communicate wirelessly with the user's PC via WiFi with a line-of-sight wireless range of 100 meters. The wireless communication allows for a quick setup with no wires underfoot, the ability to move around while troubleshooting strings, and the flexibility to measure multiple combiner boxes with a single SolSensor setup.
Turn PVA Data into Key Insights, Visualizations, and Customizable ReportsCapture data in the field with the Fluke Solmetric PVA-1500T2's PVA Application and validate the results with the Data Analysis Tool (DAT). This Data Analysis Tool is a Microsoft Excel-based solution which streamlines the analysis of PVA I-V curve data and presents analysis results in multiple formats.
This solution compiles key PV parameters in a string table, flags non-conforming strings, and delivers a statistical overview of the entire array. Additionally, it visually combines string I-V curves at the combiner box level which offers a clear depiction of consistency and identifies atypical strings. The tool also generates histograms for PV parameters across the string population. This generated data can be added to a customizable report exported as a PDF.
The Data Analysis Tool (DAT) features multi-language support and can be downloaded for use with the Fluke Solmetric PVA-1500T2.
TrainingTo get the most out of the Fluke Solmetric PVA-1500T2 unit, Fluke offers a variety of training sessions and courses (not included) related to PV testing and measurement. This training can be delivered as a virtual on-demand course or as a live online presentation and discussion format with a product expert (may differ regionally).
Brand | Fluke |
---|---|
Condition | NEW |
- 1 - PVA I-V Curve Tracer (PVA-1500T2)
- 1 - Soft Case
- 1 - AC Wall Plug Charger
- 1 - MC-4-to-Alligator Clip Test Leads, 1500V
- 1 - MC-4 Connect/Disconnect Tool
- 1 - User Manual
- 1 - SolSensor Unit
- 2 - Type-K Thermocouple Temperature Sensors
- 1 - Module Frame Clamp
- 50 - Adhesive Disks
- 1 - SolSensor Tool Lanyard
- 1 - Micro-Fiber Cleaning Cloth
- 1 - Distilled Water Spray Bottle