Ralston Instruments DCAP-PV-KIT2-VN

Pressure and Vacuum Hand Pump Calibration Kit with LC20 Digital Pressure Gauge, -15 to 500 PSI

DCAPPVKIT2VN
DCAP-PV-KIT2-VN

Ralston Instruments DCAP-PV-KIT2-VN

Pressure and Vacuum Hand Pump Calibration Kit with LC20 Digital Pressure Gauge, -15 to 500 PSI

DCAPPVKIT2VN
DCAP-PV-KIT2-VN

The Ralston Instruments DCAP-PV-KIT2-VN Pressure and Vacuum Hand Pump Calibration Kit provides users with what they need to perform calibrations.

  • Pneumatic/Vacuum Hand Pump: 650 PSI Max Pressure, -28.5 inHg Max Vacuum, 0°F to 140°F Operating Temperature Range
  • Quick-Test Hose: 6900 Max Pressure, -30 inHg Max Vacuum, -40°F to 140°F Operating Temperature Range
  • LC20 Pressure Gauge: -15 to 500 PSI (Sensor A Bottom), -4°F to 120°F Operating Temperature Range

Hand Pump (DCAP-PV)

  • Maximum Vacuum: -28.5 inHg/-96.5 kPa
  • Piston Displacement: .67 cubic in.
  • Burst Pressure: 2600 PSI/180 bar/18 MPa
  • Fine Adjustment Resolution: 0.001 PSI/7 Pa
  • Pressure Media: Air
  • Media Compatibility: Air, Inert Gas, Natural Gas
  • Fluid Media: Air
  • Materials: Anodized Aluminum, Brass, Stainless Steel
  • Maximum Pressure: 650 PSI/45 bar/ 4.50 MPa
  • Maximum Operating Temperature: 140°F
  • Minimum Operating Temperature: 0°F
  • Seal Materials: Buna-N, Delrin
  • Outlet Port: Male Quick-Test, Male Quick-Test with Cap and Chain

Reference Connection (LC20-VN2M-00-00)

  • Battery Count: 2
  • Battery Life: 1000 Hours
  • Battery Type: AA Alkaline (IEC-LR6)
  • Bluetooth Radio Installed: No
  • Calibration Certificate: ISO 17025:2017 Accredited
  • Certifications: Certified to CSA Standard C22.2 No. 61010-1, Complies with Pressure Equipment Directive 2014/68/EU, Complies with Low Voltage Directive 2014/35/EU, Complies with Electromagnetic Compatibility Directive 2014/30/EU
  • Datalogging: PC based (via USB)
  • Electrical Rating: 50 mA at 5 VDC
  • Ingress Protection: IP67 (1 meter water submersion for 30 Minutes)
  • LCD Display: 2.4 in. Segmented LCD Display
  • Materials: ABS/Polycarbonate Blend, Powder Coated Aluminum
  • Maximum Operating Temperature: 122°F
  • Minimum Operating Temperature: -4°F
  • Panel Mount: No
  • Primary Power: Battery Power
  • Process Connection Location: Bottom Mount
  • Protection Class: Pollution Degree 2 (UL / IEC 61010-1)
  • Temperature Compensation: None
  • USB Connection: USB (Micro B)
  • W1 Radio Installed: No
  • Wetted Materials: 316 Stainless Steel
  • Wireless: None
  • End 1 Connector: 1/4 in. Male NPT (ASME B1.20.1)
  • End 1 Direction: Left

Sensor A (Bottom)

  • Sensor Type: Pressure Sensor
  • Maximum Vacuum: 30 inHg / 101.6 kPa
  • Engineering Units: atm, bar, cmH2O at 39.2°F, inH2O at 102.2°F, kPa, MPa, mbar, PSI, inHg at 39°F, kgf / cm^2, mmHg at 32°F, Torr, mmH2O at 39.2°F, ft.,H2O at 39°F, cmHg at 32°F, oz / in^2
  • Maximum Operating Temperature: 122°F
  • Burst Pressure: 2000 PSI / 140 bar / 14 MPa
  • Maximum Storage Temperature: 167°F
  • Maximum Pressure: 500 PSI / 35 bar / 3.50 MPa
  • Minimum Storage Temperature: -40°F
  • Process Connection: 1/4 in. Male NPT
  • Wrench Size: 7/8 in.
  • Minimum Operating Temperature: -4°F
  • Measurement Type: Gauge Pressure
  • Media Compatibility: Air, Alcohol, Antifreeze, Ethylene Glycol, Hydraulic Oil, Inert Gas, Light Motor Oil, Mineral Oil, Natural Gas, Petroleum Based Oil, Ralston Calibration Oil, Skydrol, Transmission Fluid, Water, Windshield Washer Fluid, Oxygen (If Oxygen Cleaned)
  • Wetted Materials: 316 Stainless Steel
  • Accuracy - Pressure Measurement: +/- 0.1% of Full Scale (ASME B40.100 Grade 4A/ISO Class 0.1)

Reference Connection (QTHA-2FSA)

  • Materials: Stainless Steel
  • Maximum Operating Temperature: 225°F
  • Maximum Pressure: 5000 PSI/350 bar/35 MPa
  • Maximum Vacuum: 0 inHg/0.0 kPa
  • Wrench Size: 3/4 in.
  • End 1 Connector: 1/4 in. Female NPT (ASME B1.20.1)
  • End 1 Direction: Left
  • End 2 Connector: Female Quick-Test
  • End 2 Direction: Left

Process Connection (QTHA-2MS0)

  • Materials: Stainless Steel
  • Maximum Operating Temperature: 225°F
  • Maximum Pressure: 5000 PSI/350 bar/35 MPa
  • Maximum Vacuum: 0 inHg / 0.0 kPa
  • Minimum Operating Temperature: 0°F
  • Seal Materials: Buna-N
  • Wrench Size: 9/16 in.
  • End 1 Connector: 1/4 in. Male NPT (ASME B1.20.1)
  • End 1 Direction: Left
  • End 2 Connector: Male Quick-Test
  • End 2 Direction: Left

Hose (QSQS-HOS-3ft)

  • Burst Pressure: 27000 PSI/1860 bar/185 MPa
  • Color: Silver
  • Fluid Media: Air, Inert Gas, Natural Gas, Petroleum Based Oil, Water
  • Hose Length: 3 ft.
  • Inner Diameter: 0.08 in.
  • Materials: Stainless Steel
  • Maximum Operating Temperature: 140°F
  • Minimum Operating Temperature: -40°F
  • Maximum Pressure: 6900 PSI/475 bar/48 MPa
  • Maximum Vacuum: -30 inHg/-101.6 kPa
  • Media Compatibility: Air, Inert Gas, Natural Gas, Petroleum Based Oil, Water
  • Minimum Bend Radius: 1 in.
  • Outer Diameter: 0.2 in.
  • Type: QT
  • Hose End 1: Female Quick-Test, Stainless Steel
  • Hose End 2: Female Quick-Test, Stainless Steel

Bag (SM-0084)

  • Materials: Zippered Nylon

Case (DCAP-CASE)

  • Impact Resistance: MIL-STD-3010C
  • Ingress Protection: IP67 (1 meter water submersion for 30 Minutes), MIL-STD-810F
  • Materials: ABS Plastic, Polyethylene Foam

The Ralston Instruments DCAP-PV-KIT2-VN Pressure and Vacuum Hand Pump Calibration Kit provides users with everything that they need to perform precise and accurate calibrations. A pneumatic hand pump allows users to control pressure levels by hand when in the field. The hand pump also has a maximum vacuum of -28.5 inHg and a maximum pressure of 650 PSI. This kit provides users with a LC20 pressure reference that measures and displays readings on a large, backlit screen with a pressure range of -15 to 500 PSI. Users are also provided with a 3 ft. Quick-Test hose that has a maximum pressure of 6900 PSI. The Ralston Instruments DCAP-PV-KIT2-VN features a carrying case and accessories that users will need while in the field.

More Information
BrandRalston
ConditionNEW
  • 1 - Pneumatic and Vacuum Hand Pump (DCAP-PV)
  • 1 - Digital Pressure Gauge (LC20-VN2M-00-00)
  • 1 - 1/4 in. Male MPT x Male Quick-Test Process Connection (QTHA0-2MS0)
  • 1 - 1/4 in. Female NPT x Female Quick-Test Reference Connection (QTHA-2FSA)
  • 1 - 3 ft. Quick Test Hose (QSQS-HOS-3ft)
  • 1 - Zippered Bag (SM-0084)
  • 1 - Carrying Case (DCAP-CASE)
  • 1 - USB-A to Micro USB-B Cable (D-000040)