Tektronix TIVP1
IsoVu Galvanically Isolated High Voltage/Impedance Differential Probe with 2m Cable and Accessory Kit, 1 GHz
Tektronix TIVP1
IsoVu Galvanically Isolated High Voltage/Impedance Differential Probe with 2m Cable and Accessory Kit, 1 GHz
- Bandwidth: 1 GHz
- Rise time: 450ps
- Cable length: 2m
- Bandwidth: 1 GHz
- Rise time: 450ps
- Cable length: 2m
- 60 kV peak Common Mode Voltage
- Common mode input impedance (Typical):
- Input resistance: Galvanically isolated through the fiber optic connection
- Input capacitance: < 2 pF
- Differential DC gain accuracy: < 2%
- For use with 4 Series MSO, 5 Series MSO and 6 Series MSO Units
Applications
- Half/Full bridge designs using SiC or GaN, FETs, or IGBTs
- Floating measurements
- Power converter design
- Power device evaluation
- Switching power supply design
- Inverter design
- Motor drive design
- Electronic ballast design
- EMI and ESD troubleshooting
- Current shunt measurements
The Tektronix TIVP1 IsoVu Galvanically Isolated High Voltage/Impedance Differential Probe with 2m Cable and Accessory Kit, 1 GHz technology delivers accurate differential measurements up to ±2500 V on reference voltages slewing ±60 kV at 100 V/ns or faster. With the IsoVu Generation 2 design, users get all the benefits of IsoVu technology at 1/5 of the size of first generation probes. With versatile MMCX connectors and an unmatched combination of bandwidth, dynamic range, and common mode rejection, IsoVu Gen 2 TIVP1 probes are setting new standards for isolated probe technology and enabling wide bandgap power designs using SiC and GaN.
Benefits of IsoVu Probes
IsoVu technology uses power-over-fiber and an optical analog signal path for complete galvanic isolation between the measurement system and the DUT. By allowing the probe to float independently at the common mode voltage, isolation provides important advantages.
- 160 dB (100 million to 1) CMRR at DC
- Up to 120 dB (1 million to 1) CMRR at 100 MHz
- Up to 80 dB (10,000 to 1) CMRR at 1 GHz
- ±60 kV Common Mode Voltage range
- Up to ±2500 V differential input Voltage range
- Up to ±2500 V offset range
High Voltage and High Bandwidth
With traditional differential probes users had to choose between high bandwidth or high voltage levels. TIVP1, with their shielded coaxial cable and isolation, provide high bandwidth and a differential voltage range of ±2500 V. TIVP1 IsoVu Gen 2 offers a bandwidth of 1 GHz to fit the user's performance needs.
High Performance and Convenient Connections
TIVP1 IsoVu probe tips have a range of connections and accessories that offer high performance and accessibility. The probes can connect directly to MMCX connectors, which are inexpensive and widely-available. This makes for stable, hands-free test points and offer high bandwidth and common mode rejection. The solid metal body shields the center conductor and minimizes ground loop area for the lowest interference possible.
Other accessories are available to adapt the probe tips to a wide range of connections. Additional 0.100 in. and 0.200 in. spaced square-pin tips are available for applications that require greater than ±250V differential voltage. When not using a tip, the sensor head has 1 MΩ and 50Ω switchable termination at the probe's SMA connector. This feature effectively adds an isolated channel to any compatible oscilloscope.
Floating Measurements in Power Converter and Motor Drive Designs
Making high-side measurements in half-bridge power converters is challenging because the source or collector to which the measurements are referenced is slewing rapidly up and down. Wide bandgap devices like SiC and GaN FETs are even harder to measure because they can switch high voltages in a few nanoseconds. Noise from this rapidly changing common mode voltage leaks into the differential measurements and hides details on VGS and VDS. TIVP1 IsoVu probes have unmatched common mode rejection at full bandwidth that lets users see signal details, often for the first time.
Country of Origin | United States |
---|---|
Brand | Tektronix |
Condition | NEW |
- 1 - IsoVu Galvanically Isolated High Voltage/Impedance Differential Probe with 2m Cable and Accessory Kit, 1 GHz
- 1 - IsoVu Soft Carrying Case with Foam Insert
- 1 - 5/16 in. SMA Wrench/Driver Tool
- 1 - Probe Tip Adapter
- 1 - Probe Bipod for Probe
- 1 - MMCX Probe Tip
- 1 - Certificate of Traceable Calibration
- 1 - Quickstart Guide