Teledyne LeCroy CP031A
AC/DC High Sensitivity Current Probe, 100 MHz, 30 A RMS, 50 A Peak Pulse, 1.5 Meter Cable, for WaveSurfer 3000z Units
Teledyne LeCroy CP031A
AC/DC High Sensitivity Current Probe, 100 MHz, 30 A RMS, 50 A Peak Pulse, 1.5 Meter Cable, for WaveSurfer 3000z Units
The Teledyne LeCroy CP031A High Sensitivity Current Probe allows for more precise, low current measurements on Teledyne LeCroy oscilloscopes. It can obtain highly accurate, low current waveforms with unmatched 12-bit resolution for improved debug and analysis.
- 30A, 100MHz High Sensitivity Current Probe
- Max continuous currents ranging from 30 Arms to 500 Arms
- Max peak currents from 50 Apeak to 700 Apeak
- Wide bandwidths from 2 MHz to 100 MHz
- 30A, 100MHz High Sensitivity Current Probe
- Max continuous currents ranging from 30 Arms to 500 Arms
- Max peak currents from 50 Apeak to 700 Apeak
- Wide bandwidths from 2 MHz to 100 MHz
- ProBus active probe interface with automatic scaling in A/div
- Autozero and degauss capabilities built into user interface
- Sensitivity down to 1 mA/div
- Precise voltage and current deskew with DCS015 deskew calibration fixture
- 30A RMS continuous current
- 50A peak current
- 100 MHz bandwidth
- 1 mA/div sensitivity
The Teledyne LeCroy CP031A provides a high sensitivity of 1mA/div. This allows for more precise low current measurements on Teledyne LeCroy oscilloscopes. When used with HDO high definition oscilloscopes with HD4096 technology, users will obtain highly accurate, low current waveforms with unmatched 12-bit resolution for improved debug and analysis.
Fully Integrated
All Teledyne LeCroy current probes are powered through the Teledyne LeCroy ProBus connection and require no additional hardware. Along with providing power, the ProBus connection allows the current probe and oscilloscope to communicate, resulting in current waveforms automatically displayed on screen in Amps, and calculated power traces scaled correctly in Watts. This full integration also allows for the Degauss and Autozero functions to be done directly from the oscilloscope’s user interface.
Deskew Calibration Source
The DSC015 deskew calibration source has both voltage and current time-aligned signals, which enables the precise deskew of voltage and current probes. Most voltage probes along with the CP030, CP030A, CP031, and CP031A are compatible with the DSC015.
Country of Origin | Japan |
---|---|
Brand | LeCroy |
Condition | NEW |
- 1 - CP031A AC/DC High Sensitivity Current Probe