Teledyne LeCroy T3RC3000-LF

AC Rogowski Current Probe 2 mV/A, 3,000A, 0.11 Hz LF Bandwidth, 6.5MHz HF Bandwidth, 4m Cable, 300mm Coil

T3RC3000LF
T3RC3000-LF

Teledyne LeCroy T3RC3000-LF

AC Rogowski Current Probe 2 mV/A, 3,000A, 0.11 Hz LF Bandwidth, 6.5MHz HF Bandwidth, 4m Cable, 300mm Coil

T3RC3000LF
T3RC3000-LF

The Teledyne LeCroy T3RC3000-LF AC Rogowski Current Probe offers a bandwidth of < 0.2 Hz to 6.5 MHz and a maximum current measurement coverage up to 3000 Amps for maximum application coverage whilst being easy to use in difficult to reach parts of the circuit.

  • Current measurement coverage up to 3000 Amps
  • Voltage insulation up to 10 kV
  • Connect to wall plugs or use with batteries
  • Low loading of circuits under test
$1,900.43 Price $1,910.00
This item ships FREE
  • Current measurement coverage up to 3000 Amps
  • Voltage insulation up to 10 kV
  • Connect to a wall plug or use with batteries
  • Low loading of the circuit under test
  • Wide coil operating temperature from -20 C to +100 C
  • Use without modification to the DUT

The Teledyne LeCroy T3RC3000-LF Rogowski Current probe offers a bandwidth of < 0.2 Hz to 6.5 MHz and a maximum current measurement coverage up to 3000 Amps for maximum application coverage whilst being easy to use in difficult to reach parts of the circuit.

The flexibility of the probe sense coil means that measurements can often be made without modification to the circuit under test, giving more accurate results, whilst remaining isolated, with very low insertion load of only a few pH.

The inclusion of both battery power and wall plug operation means that the T3RC3000-LF current probe is as happy working out in the field as it is working on the bench.

The T3RC3000-LF Rogowski probe offers an extended low frequency performance down to less than 1 Hz. The low frequency performance means that the maximum droop on low frequency pulses is typically 0.1%/ms or less, whilst offering our highest level of peak insulation of 10 kV and wide operating temperature range of -20 °C to +100 °C.

The T3RC3000-LF probe is compatible with all of the Teledyne LeCroy Oscilloscopes. The probe has a simple connection requirement of a BNC input with 1 MOhm impedance. These probes will therefore work with the majority of oscilloscopes in the market. The probe can be made even more useful by using your Oscilloscope's Attenuation function to re-scale the Channel vertical range.

More Information
Country of OriginUnited Kingdom
BrandLeCroy
ConditionNEW
  • 1 - AC Rogowski Coil Current Probe (T3RC3000-LF)
  • 1 - Set of Batteries
  • 1 - Power Line Adapter
  • 1 - BNC Cable
  • 1 - Storage Box