Wayne Kerr 6550B/B1
*Internal Option* Bin Handler (Non-Isolated 5V) for 6550B Precision Impedance Analyzer
Wayne Kerr 6550B/B1
*Internal Option* Bin Handler (Non-Isolated 5V) for 6550B Precision Impedance Analyzer
- Bin handler (non-isolated 5V) for model 6550B Precision Impedance Analyzer
- Available through a 25-way D-type connector
- 10 bins can be set using absolute or percentage limits
- Precise high frequency impedance measurements
- 0.05% basic measurement accuracy
- Comprehensive measurement functions
- Easy to use with large TFT touch screen
- Clear graphic displays
- Intuitive user interface
- Fully programmable over GPIB
- Equivalent Circuit Analysis function
Wayne Kerr 6550B/B1 Binning Option for the 6550B 20Hz - 50MHz Precision Impedance Analyzer (Cannot be fitted together with the 6550B/B2).
The Wayne Kerr 6550B 20Hz - 50MHz Precision Impedance Analyzer provide precise and fast testing of devices at frequencies up to 120 MHz. Basic measurement accuracy is ±0.05% making the instruments the best in their class.
The accuracy and versatility makes these precision instruments the ideal choice for many different tasks and applications including passive component design, dielectric material testing and resonant frequency characterization.
AC Measurement parameters: Impedance (Z)
Phase Angle (Ø)
Capacitance (C)
Dissipation Factor (D)
Inductance (L)
Quality Factor (Q)
Resistance (R)
Reactance (X)
Conductance (G)
Susceptance (B)
Admittance (Y)
High measurement accuracy
Capacitance, inductance and impedance basic accuracy are all an excellent ±0.05%. Dissipation factor accuracy is ±0.0005 and the quality factor accuracy is ±0.05%.
Graphical sweep of components
The 6500B series of Precision Impedance Analyzers are highly accurate high frequency component analyzers with a host of useful features.
Graphical sweep of two measured parameters is available and displayed on the large clear colour display. Swept parameters are frequency, drive level and DC bias.
Display formats available include series or parallel equivalent circuit.
An Equivalent Circuit Analysis function is available. This allows modelling and curve fitting to various models of equivalent circuits. 4 types of 3-component model and 1 type of 4-component model can be selected. The instrument will calculate the nearest equivalent circuit parameters for the measurement traces and revise the results for the different models instantly. Alternatively the parameters can be entered by the user and the instrument will plot the resulting frequency characteristics and revise the plot between the various models instantly.
For single frequency measurements a meter mode is available.
Variable drive and bias levels: AC drive levels up to 1V or 20 mA can be selected to evaluate components in realistic operating environments. /D1 DC bias option provides 0 to +40V dc bias voltage and 0 to +100mA dc bias current. /D2 option provides -40V to +40V dc bias voltage.
External control: The GPIB interface is used to control the instrument and read back measured values for applications such as quality control or for archiving purposes.
An Ethernet interface similarly allows the instrument to be controlled and to send out data, allowing it to be integrated into many test environments.
Wide range of interfaces: An external monitor or projector may be connected to the instrument’s VGA output. The ability to provide a large screen display of measurement results is invaluable in production environments or for teaching and training.
Instrument control from both a keyboard and mouse is available. Any keyboard or mouse, with either PS/2 or USB interfaces, can be simply connected to provide an alternative method of instrument control and operation.
Data storage and retrieval: All measurement and setup data can be stored using the Ethernet interface or a USB flash memory (supplied as standard).
Setup Data: Up to 20 instrument setups may be locally stored.
Bin handling: /B1 option (non-isolated 5V) or /B2 option (isolated 24V) signals are available through a 25-way D-type connector. 10 bins can be set using absolute or percentage limits.
Printer outputs: Hard copy printouts can be obtained in a number of ways including direct to an HP-PCL compatible graphics printer or Epson compatible text/ticket printer. A networked HP-PCL compatible printer may also be used via the Ethernet connection.
Component connections: Four front panel BNC connectors permit three or four terminal connections with the screens at ground potential.
The 1J1011 Component Fixture, supplied with all models, ensures optimum performance when measuring a wide range of leaded components and devices.
The 1J1011 Component Fixture, supplied with all models, ensures optimum performance when measuring a wide range of leaded components and devices.
Protection against charged capacitors: High precision measuring instruments can be damaged by charged capacitors which can cause costly repairs and unacceptable downtime. All the models in the range incorporate protection against charged capacitors.
Comprehensive and precise component tests at higher frequencies: The 6500B series is best summarized by "Comprehensive and precise component tests at higher frequencies". The instrument is the perfect solution for those who have demanding component measurement needs.
Brand | Wayne Kerr |
---|---|
Condition | NEW |
- 1 - Operation Manual
- 1 - AC power cord
- 1 - 1J1011 Fixture
- 1 - USB memory
- 1 - Pen/stylus
- 1 - Calibration Certificate