The Yokogawa TX1003 2-Channel Multi-Function Digital Thermometer supports K, J, E and T type thermocouples. It has a user calibration function and keys for input channel select, data hold, max and min record, data record, resolution select, relative display, data-call up, and simplified correction mode.

  • Input Channels: 2
  • Measuring Range:
    • Type E: -328 to 1292°F
    • Type J: -328 to 1832°F
    • Type K: -328 to 2501.6°F
    • Type T: -328 to 752°F
This product is available for shipping to the US, Canada, and Puerto Rico only.
$260.00
This item ships FREE
  • Memory-in Function: Up to ten data items can be stored; when recalled, stored data value is displayed with its memory number
  • User calibration function: Calibration and adjustment can be mode easily by operating panel keys on instrument and measurement-standard
  • Thermocouple type (K, J, E, and T) select key
  • Input channel select key: With each press, channel switches through sequence of "chA," "chB," and then "chA-chB"
  • Data hold key: Held measured value, can be stored in memory of optional memory number, which is selected with up, down keys
  • Maximum and minimum record key: Stores maximum and minimum values from time RECORD key is pressed
  • Data record key: Stores the held measured value in memory (Up to ten)
  • Resolution select key: With each press, resolution alternates between 0.1°C and 1°C (within range of -200.0°C to 199.9°C)
  • Maximum and minimum values, and stored data read key: Every time key is pressed, maximum and minimum values, stored data, and current measured data are displayed in sequence
  • Relative display select key: Displays measured values with reference to value obtained immediately before this key was pressed (relative value); each press of key can select or release the relative display
  • Simplified correction mode key: Sets the correction value, and selects active/inactive of simplified correction function
  • Data call-up key: Used to select memory number when calling up stored data; also used to adjust correction value for simplified correction mode
  • Number of Input channels: 2
  • Measuring Range:
    • Type E: -200 to 700°C (-328 to 1292°F)
    • Type J: -200 to 1000°C (-328 to 1832°F)
    • Type K: -200 to 1372°C (-328 to 2501.6°F)
    • Type T: -200 to 400°C (-328 to 752°F)
  • Resolution:
    • -200.0°C to 199.9°C: 0.1°C or 1°C (when 1°C resolution is set)
    • +200°C or above: 1°C
  • Accuracy:
    • +200 °C or above, or when 1°C resolution is set ±(0.2% of rdg + 1°C)
    • -100.0°C to 199.9°C ±(0.1% of rdg + 0.7°C)
    • -200.0°C to -100.1°C ±(0.1% of rdg + 1.0°C)
  • Temperature Coefficient: ± (0.015% of rdg +0.06°C)/°C
  • Approx. Measurement Interval: 2 sec
  • Data Storage: Capable of storing up to 10 measured data items
  • Simplified Correction: Correction range: ±20°C of measured value
  • Display Item: HOLD, RCD, REL, ADJ, MAX, MIN, MEM, °C chA, chB, chA-chB TC type K, J, E, T Battery alarm
  • Other Functions
  • Auto power-off, battery alarm
  • Display: LCD
  • Operating Temperature: 0 to 50 °C
  • Humidity: 80% RH (no condensation)
  • Power Requirements: Two AA-size alkaline dry batteries (LR6)

Applications

  • Temperature management in refrigerated warehouse
  • Temperature checks in equipment maintenance
  • Temperature management for research and development
More Information
BrandYokogawa
ConditionNEW
  • 2 - AA Alkaline Dry Batteries (LR6)
  • 1 - User Manual