Fluke 709H
Precision Loop Calibrator with HART Communications/Diagnostics
The Fluke 709H is a Precision Loop Calibrator designed to save time and produce high-quality results. This calibrator is built around a user friendly interface with a quick-set rotary encoder knob. It reduces the time it takes to measure or source current, and power up a loop.
- Accuracy: 0.01% reading
- Compact, rugged design
- Intuitive user interface with quick-set knob
- Built in selectable 250 Ohm resistor for HART communications
- Accuracy: 0.01% reading
- Compact, rugged design
- Intuitive user interface with quick-set knob for fast setup and easy use
- 24V DC loop power with mA measure mode (-25% to 125%)
- Resolution of 1 μA on mA ranges; 1mV on voltages ranges
- Built in selectable 250 Ohm resistor for HART communications
- Simple, two-wire connection for all measurements
- Auto shutdown to conserve battery life
- Variable step and ramp time in seconds
- Valve test (source and simulate defined mA values with % keys)
The Fluke 709H Precision Loop Calibrator with HART Communications/Diagnostics is designed to save time and produce high-quality results. This calibrator is built around a user friendly interface with a quick-set rotary encoder knob. This tool reduces the time it takes to measure or source current, and power up a loop. The large, backlit display is easy to read, even in dark, cramped worked areas.
Hart Communications
The 709H adds HART communications and supports a select set of the HART universal and common practice commands. This makes the 709H unique as both an affordable, compact loop calibrator and powerful HART communication troubleshooting tool.
In the communicator mode the user will be able to read basic device information, perform diagnostic tests, and trim the mA output on most HART enabled transmitters. In the past, this could only be done with a dedicated communicator, a high-end multifunction calibrator, or a laptop computer with a HART modem. Fluke 709H will allow virtually any technician to service and support HART devices.
Data logged mA loop measurements and HART data can be recorded from a particular transmitter for troubleshooting and loop tuning. The data log feature offers selectable capture with recording intervals of 1 to 60 seconds and a logging capacity of 9800 records or 99 individual sessions. Each data sample contains the 709H mA measurement, all four process variables, and the standard status conditions.
Country of Origin | China |
---|---|
Brand | Fluke |
Catalog | 4234361 |
Condition | NEW |
UPC | 095969643757 |
Vendor Alias | FLUKE-709H |
- 1 - Test Lead Set (TL-75-4201)
- 2 - Alligator Clip Sets (AC72-1)
- 1 - Alligator Clip Set (754-8016)
- 1 - Stackable Lead Set (75X-8014)
- 1 - Test Probe Set (TP220-4201)
- 6 - AAA Batteries
- 1 - Soft Carrying Case
- 1 - Quick Reference Guide
- 1 - User Manual