The Fluke 729PRO 7M is an Automatic Pressure Calibrator designed for technicians to simplify pressure calibration and provide faster, more accurate test results. This unit's automatic internal electric pump allows for a target pressure to be set and automatically pumped to the desired pressure via the calibrator.

  • Pressure Control Range: -13 to 1000 psi, -90 to 7000 kPa, -0.90 to 70 bar
  • HART communication capabilities for mA and pressure value adjustments
This product is available for shipping to the US, Canada, and Puerto Rico only.
  • Automatic pressure generation/regulation to 1000 psi, 7 MPa
  • Replaceable pressure control modules
  • Fast to high pressure setpoints
  • Built-in test template, easy one-button documented calibration
  • HART communication
  • Pressure leakage testing
  • Automatic fine-pressure adjustment, automatic pressure stabilization
  • Powerful Li-ion battery
  • Extend measurement range with 750P Series pressure modules
  • Measure temperature with 720RTD probe
  • Bright dual-three-channel/color graphic display
  • Rugged, portable design

Key Parameters:

  • Pressure Control Range: -13 to 1000 psi/-90 to 7000 kPa/-0.90 to 70 bar
  • Pressure Type: Gauge/Absolute (Depends on type of pressure module)
  • Control Stability: 0.005 % of FS, minimum
  • Built-in Replaceable Pressure Control Modules: 6 modules
  • External Pressure Measurement Modules: 750 Series pressure modules, 50 models ranging from 0 to 1 in H2O, 2.5 mbar, 250 Pa to 10,000 psi, 70 bar, 7 MPa
  • mA Sourcing/Measurement: Yes
  • Voltage Measurement: Yes
  • Loop Power: 24V DC
  • One-key Calibration: Task templates make documented automatic calibrations easy
  • Pressure Switch Testing: Yes
  • Pressure Leakage Testing: Yes
  • HART: Yes
  • Autostep/Auto Ramp: Yes (with customizable speed, mode, style)
  • Log Function: Yes
  • Software: DPCTrack2 Calibration/Asset Management Software
  • One-key pressure-relief: Yes (muffler)
  • Battery: Rechargeable lithium battery with capacity indication (charged with instrument or separately)
  • Language: English/Simplified Chinese

Specifications:

Pressure Specifications

  • 1-year Specifications: 0.02% of FS
  • Control Specifications: 0.005% of FS

Electrical Specifications (*All specifications are valid to 110% of range, except 24 mA sourcing/simulating which are valid to 100% of range)

  • mA Measure, Source, Simulate: 0 mA to 24 mA (resolution of 1 μA)
  • Volts DC Measurement: 0V DC to 30V DC (resolution of 1 mV)
  • Accuracy: 0.01% FS ± 2 LSD (23°C ± 5°C)
  • Stability: 20 ppm FS/°C (-10°C to +18°C / 28°C to 50°C)
  • Loop Compliance Voltage: 24V DC @ 20 mA
  • mA Simulation Working Voltage: 12V DC to 30V DC
  • Temperature Measurement, 100 Ω Pt (385) RTD: -50°C to +150°C (-58°F to 302°F)
  • Temperature Resolution: 0.01°C (0.01°F)
  • Temperature Accuracy: ± 0.1°C (0.2°F) ± 0.25°C (± 0.45°F) combined uncertainty when using 720 RTD probe (optional accessory)
  • Drive Capability (mA Source): 1200 Ω (without HART resistor), 950 Ω (with internal HART resistor)

Mechanical Specifications

  • Dimensions: (H x W x L) 290mm x 215mm x 100mm (11.4 in x 8.5 in x 3.9 in)
  • Weight: 4.9 kg (10.89 lb)

Environmental Specifications

  • Operating Temperature: -10°C to 50°C
  • Pressure Control: 0°C to 50°C
  • Battery Charging: 0°C to 40°C
  • Storage Temperature: -20°C to 60°C
  • Operating altitude: < 3000m
  • Storage Altitude: < 13000m
  • Operating Humidity: Non-condensing (< 10°C), ≤ 90 % RH (10°C to 30°C), ≤ 75 % RH (30°C to 40°C), ≤ 45 % RH (40°C to 50°C)

Safety

  • General: IEC 61010-1, pollution degree 2
  • Lithium Battery: IEC 62133, UN 38.3; 14.4V, 6.7Ah, 97Wh, 4ICR19/66-2 (4s2p) Charge input 19.5V, 1.6A

The Fluke 729PRO7M Automatic Pressure Calibrator is designed specifically for process technicians to simplify pressure calibration and provide faster, more accurate test results.

With an automatic internal electric pump, a target pressure can be set in the 729PRO 7M and the calibrator automatically pumps to the desired pressure. Internal fine adjustment control then automatically stabilizes and holds the pressure at the desired value.

The Fluke 729PRO 7M can also automatically test multiple pressure test points and automatically document the results. Calibration is as easy as typing in the starting and ending pressure, the number of test points, and tolerance level. The 729PRO 7M does the rest of the work once these settings are calibrated.

Built-in HART communication capabilities enable HART transmitter mA adjustments, light HART configuration, and the ability to adjust to applied 0% and 100% pressure values. HART communication enables mA output trim, trimmed to applied values, and pressure zero trimming of HART pressure transmitters. Users can easily change a transmitter tag, measurement units, and ranges. Other supported HART commands include setting fixed mA outputs for troubleshooting, reading device configuration parameters, and reading device diagnostics.

The Fluke 729PRO 7M performs automatic pressure calibration with excellent portability of less than 5 kg. Engineers and technicians are no longer restricted by the environment and can perform efficient calibration at will. The 729PRO 7M can be widely used in electric power, petroleum, chemical, pharmaceutical, metrology, metallurgy, biology, food, transportation and automobile manufacturing.

Automatic pressure generation and regulation to 7 MPa (70 bar, 1000 psi)

Enter a pressure up to 7 MPa and the 729PRO 7M will automatically pump to the desired pressure. It can also output changing pressure in step values or a linear ramp.

Easy calibration documentation using well-defined templates for transmitters and switches

Type in the starting and ending test pressures and number of test points, the 729PRO 7M does the rest by documenting the applied pressure, measured mA and % error for each test point. The bright color graphical display will flag test results that are out of tolerance in red.

Replaceable pressure control modules

Freely switch the pressure output range to achieve range matching without having to buy a complete new calibrator.

Powerful Li-ion battery

The lithium battery equipped can be charged separately or with the device along with a capacity indicator to confirm the power before installation. It is easy to replace the battery without any tools.

More Information
BrandFluke
ConditionNEW
  • 1 - Automatic Pressure Calibrator with Pre-Installed Battery (729PRO 7M)
  • 1 - Set of Test Leads
  • 1 - User Manual
  • 1 - Carrying Case
  • 1 - Shoulder Strap
  • 1 - Hose Kit
  • 1 - Set of Adapters