Megger BVM150
System of 16 BVM Battery Voltage Monitors with Clamps, Accessories, and Case
Megger BVM150
System of 16 BVM Battery Voltage Monitors with Clamps, Accessories, and Case
The Megger BVM150 (CJ-59092) System of 16 BVM Battery Voltage Monitors is a battery cell/block voltage measurement system that is performed on battery banks. The BVM system is designed in a modular form where one BVM unit is used for each cell or block in the battery string to be tested.
- Daisy-chain design allows expandability up to 2 x 120 cells
- High accuracy/stability for precise data collection
- Automates battery voltage measurement during capacity tests
- System consists of 16 BVM Battery Voltage Monitors
- Equipment entails battery cell/block voltage measurement system performed on battery banks
- Ideal for capacity testing large industrial battery banks
- Compatible with TORKEL Load Devices (sold separately)
- Integrates with TORKEL Win and PowerDB Test Data Management software to measure cell/block voltages from PC
- Facilitates execution of automated battery bank test according to IEC/IEEE standards when paired with load device and test data management software
- Automated battery bank test meets NERC/FERC requirements
- Modular form involves one BVM unit being used for each cell/block in battery string to be tested
- One BVM unit for each cell/block connects to next BVM unit in daisy-chain fashion
- Daisy-chain design allows for expandability up to 2 x 120 cells
- Dolphin clips can be easily removed and exchanged for standard banana plug clamps or extension cables (both sold separately)
- Identical design of each BVM unit allows for connection in any battery test position for maximum flexibility and interchangeability
- 'Auto Discovery' feature enables host device to automatically determine number of batteries under test
- Provides sequential identification of each BVM unit in test string with 'Auto Discovery' feature
- Automates battery voltage measurement during capacity tests
- High accuracy and stability for precise data collection
- Easy set-up with many options for connecting BVM system to battery bank
- Wide voltage range
Applications
- Battery rooms in electric power generating and substations
- Telecommunication infrastructure and facilities
- Computer data center UPS systems
Specifications
General
- Mains Voltage: 100V to 240VAC, 50/60 Hz
- Power Consumption: 50VA max.
- Protection: Overvoltage, reverse voltage, voltage transients, ESD
- Data Storage and Communication: USB
- Power Source: Power over Ethernet (PoE)
Measurements
- Maximum Number of BVM Units: 242 (2 x 121)
- Voltage Range: 0V to 20VDC
- Battery String Voltage: 300VDC max. per loop
- Measurement Input Impedance: 1 MΩ
CE Markings
- LVD: 2014/35/EU
- EMC: 2014/30/EU
- RoHS: 2011/65/EU
The Megger BVM150 (CJ-59092) System of 16 BVM Battery Voltage Monitors is a battery cell/block voltage measurement system performed on battery banks. This system can be used in conjunction with a load device such as the TORKEL and can be used to measure cell or block voltages from a PC with TORKEL Win or PowerDB software (additional equipment and software sold separately). The BVM system is designed in a modular form where one BVM unit is used for each cell or block in the battery string to be tested. One BVM unit for each cell or block connects to the next in a daisy chain fashion. The included dolphin clips can easily be removed and exchanged with different styles of standard banana plug clamps or extension cables to accommodate any battery connection requirement.
Up to 2 x 120 BVMs can be daisy chained in a single battery bank under test that is used for the capacity testing of large, industrial battery banks commonly found in electrical power substations, telecom facilities, and UPS systems generally. When used in conjunction with a load device, such as the Megger TORKEL, and test data management software, such as TORKEL Viewer, PowerDB, or TORKEL Win, the BVM system facilitates the execution of an automated battery bank capacity test according to IEC and IEEE standards. The test also meet NERC/FERC requirements. The BVM system is designed in a modular form where one BVM device is used for each battery cell or 'jar' in the string to be tested. One BVM for each battery connects to the next in a 'daisy-chain' fashion, thereby providing easy and economical expandability to meet the testing requirements for small-to-large battery bank systems.
Setting up the BVM system for a test is quick and easy. Each BVM unit is identical and can be connected in any battery test position, thus providing maximum flexibility and interchangeability of the BVMs. The BVM 'Auto Discovery' feature enables the host device to automatically determine the number of batteries under test and provide sequential identification of each BVM unit in the test string.
Application Testing
Each BVM unit is identical and can be connected in any battery test position. A single cable connects the first BVM unit in the string to a power and signal connector. The BVM system data output is connected via an Ethernet cable to the BVM's USB port on the TORKEL900 or to a PC with data management software. The BVM system can be used together with older Megger TORKEL versions or any battery load bank. This setup requires the use of a separate PC with test management software. The red dolphin clip in the chain should be connected to the most positive battery pole in the battery bank. The voltage over each BVM device will be logged throughout the complete discharge test.
Brand | Megger |
---|---|
Condition | NEW |
- 16 - BVM Units
- 15 - Dolphin Clips, Black
- 1 - Dolphin Clip, Red
- 1 - USB Extension Cable, 2m
- 16 - Ethernet Cables, Black, 0.5m
- 1 - Ethernet Cable, Red, 2m
- 1 - Power and Signal Connector
- 1 - Power Supply, 24VDC
- 1 - Main Lead
- 1 - Accessory Bag
- 1 - Carrying Case
- 1 - Quickstart Guide