Telaire T8200-D-GN

Ventostat, 24 Occupancy CO2/P Temp, Display, UWht

T8200DGN
T8200-D-GN

Telaire T8200-D-GN

Ventostat, 24 Occupancy CO2/P Temp, Display, UWht

T8200DGN
T8200-D-GN
  • Dual-channel optical system and three-point calibration process for enhanced stability, accuracy and reliability.
  • LCD Display
$446.84
This item ships FREE
  • Dual-channel optical system and three-point calibration process for enhanced stability, accuracy and reliability.
  • LCD Display
  • Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low cost package
  • Patented ABC Logic self-calibration system eliminates the need for manual calibration in most applications
  • Lifetime CO2 calibration guarantee when using ABC Logic
  • Mounting plate with two-piece terminal blocks provide quick, easy wiring
  • Gas permeable, water resistant CO2 diffusion filter prevents particulate and water contamination of the Transmitter
  • Locking screw secures cover and Transmitter to the mounting bracket for tamper resistance
  • Dual simultaneous analog outputs (V & mA) available for CO2
  • Transmitters are shipped factory calibrated
  • Temperature Transmitter on all models
  • Modern enclosure with customized branding available
  • CO2, humidity and temperature models
  • Two-piece design allows unit to be replaced without the need for rewiring

Ventilation is an important part of maintaining a comfortable, healthy, productive environment for people. Improper ventilation can have a negative impact on occupant health and performance, increase the risk from litigation, and/or waste energy. Demand-controlled ventilation using CO2 Transmitters prevents energy losses from over-ventilation while maintaining indoor air quality. The most energy savings potential is in buildings where occupancy fluctuates during a 24-hour period. Numerous organizations now require and/or recommend CO2-based ventilation control in different commercial HVAC applications. Some utility companies also offer rebates to building owners for installing CO2 Transmitters.

Wall mount Transmitters are used to control a specific area such as a conference room, classroom, meeting hall, etc. The Telaire T8200-D-GN Ventostat series are easy to install and have a clean, modern look that suits most indoor environments.

GE Telaire Ventostat T8200-D-GN CO2 duct mount Transmitter uses a dual-channel optical system and three-point calibration process for enhanced stability, accuracy and reliability. Used in applications where there is full-time occupation 24 hours a day.

Dual Channel Transmitter

The GE Telaire T8200-D-GN dual channel Transmitter can be described as a CO2 channel that measures gas concentration and a reference channel that measures the Transmitter signal intensity. The dual channel Transmitter performs periodic self-calibrations using the reference channel. The self-calibrations are approximately every 24 hours. During the self-calibration the Transmitter ppm reading is frozen, it will not react to changing CO2. The calibration time is adjustable but nominally two minutes.

GE recommends periodic gas calibration depending on the application accuracy requirements. While the reference channel corrects for changes over time, a field calibration using nitrogen gas or alternatively ambient calibration will immediately restore the highest level of accuracy.

More Information
BrandTelaire
ConditionNEW
Vendor AliasT8200-D-GN