A&D Weighing RA30-106

2-Channel Temperature Module with Sensor Connectors

RA30106
RA30-106

A&D Weighing RA30-106

2-Channel Temperature Module with Sensor Connectors

RA30106
RA30-106

The A&D Weighing RA30-106 2-Channel Temperature Module can set three measurement ranges for each thermocouple (TC) and platinum resistance temperature detector (RTD) sensor, and perform 16-bit sampling with a three-stage data update rate to enable A/D conversion.

  • Number of Channels: 2
  • Measure temperature with thermocouple and RTD
  • Update Rate: 1.5ms, 100ms, 1s
  • A/D Resolution: 16 bit
  • For use with Omniace RA3100 Data Acquisition System
$1,250.00
This item ships FREE

Key Specifications

  • Input Channels: 2
  • Input Connector:
    • Removable socket (front panel)
    • Temperature Sensor Connector Coupling Wire: 0.2 SQ to 1.5 SQ (AWG24 to AWG16)
  • Input Type: Isolated unbalanced input (isolation: between channels, between each channel and chassis)
  • Input Impedance: 5MΩ or higher
  • Adaptive Sensor:
    • Thermocouple: K, E, J, T, N, R, S, B, C (JIS C1602:2015)
    • Resistance Temperature Detector (RTD): Pt100, Pt1000 (JIS C1604:2013)
  • A/D Converter:
    • A/D Resolution: 16bit
    • Data Update Rates: high speed (1.5ms), normal speed (100ms), low speed (1s)
  • Common Mode Rejection Ratio: 100dB (Data update: normal speed, low speed), 80dB (Data update: High speed) at 50/60Hz, Signal source resistance 1kΩ
  • Allowable Input Voltage: 30V peak
  • Maximum Rated Voltage to Earth: 300V AC/DC (between channels, between input terminals and chassis)
  • Withstand Voltage: 3kV AC, 1 minute (between channels, between input terminals and chassis)
  • Dimensions: Approx. 140 (input-side W) x 223(D) x 20(H) mm
  • Weight: Approx. 300g
  • Compliance Standards:
    • Safety: EN61010-1, EN61010-2-30
    • EMC: EN61326-1, Class A
  • Accessories: Temperature sensor connection connector (RA30-555), 2pcs/sets

The A&D Weighing RA30-106 2-Channel Temperature Module can set three measurement ranges for each thermocouple (TC) and platinum resistance temperature detector (RTD) sensor, and perform 16-bit sampling with a three-stage data update rate to enable A/D conversion. It includes functions for switching the internal/external reference junction and checking for disconnections. It is insulated between each channel and between input and output, to safely support general temperature measurement. Thermocouples can be used for high temperatures and wide temperature ranges, while resistance thermometers can be used to measure temperatures near room temperature with high accuracy.

More Information
Country of OriginJapan
BrandA n D Weighing
ConditionNEW
  • 1 - 2-Channel Temperature Module (RA30-106)
  • 2 - Temperature Sensor Connectors (RA30-555)