AEMC Power Quality/Energy Logger PEL 100 Series - Monitor your power and energy usage and cost locally or from anywhere in the world! Promotional BannerAEMC Power Quality/Energy Logger PEL 100 Series - Monitor your power and energy usage and cost locally or from anywhere in the world! Promotional Banner

AEMC PEL-100 Series


PEL-100 Series Features


PEL-100 Device In FieldPEL-100 Device In Field

Overview

  • Simple-to-use, single-, dual- (split-phase) and three-phase (Y, ∆) power & energy loggers
  • Designed to work in 1000V CAT III and 600V CAT IV environments
  • Power measurements: kVA, kW and vkar
  • Energy measurements: kVAh, kWh (source, load) and kvarh (quadrant indication)
  • 8GB SD card supplied, can be upgraded up to 32GB
  • USB, LAN, Ethernet and Bluetooth
  • Satisfies the monitoring requirements of NEC Code 220.87
  • PEL 103 can be configured from front panel, DataView® control panel or the FREE Android™ application
  • Provides all the necessary functions for power and energy data logging for 50Hz, 60Hz, 400Hz and DC distribution systems
  • Automatic recognition of the connected current sensors and probes
  • Magnetic case – can be mounted inside power panel
  • Supports 17 network configurations

Applications

  • Power and electric monitoring
  • Harmonic detection and analysis
  • Utility testing
  • Energy management
  • Power factor analysis and correction
  • Power demand and consumption
  • kW measurement
  • Industrial power systems
  • Commercial maintenance

Large Functional Displays


Information and Measurement ModesInformation and Measurement Modes

Information Mode

The PEL103's information mode allows hook up, voltage and current ratios and aggregation period to be configured from the front panel.

Measurement Mode

Real-time updates are displayed for voltage, current, power, frequency, power factor and tangent.

Max and Harmonic ModesMax and Harmonic Modes

Max Mode

Max Values for voltage, current (including neutral current), power and harmonics.

Harmonic Mode

Total Harmonic Distortion (THD) can be displayed by phase or phase to phase. Neutral current THD can also be displayed.

Configure PEL 103 and PEL 105 directly from front panel, DataView® control panel, or Android App


Configure all functions of the PEL

  • Display and analyze real-time data on your PC
  • Configure functions and parameters from your PC
  • Customize views, templates and reports to your exact needs
  • Create and store a complete library of configurations that can be uploaded as needed
  • Zoom in and out and pan through sections of the graph to analyze the data
  • Download, display and analyze recorded data
  • Display waveforms, trend graphs, harmonic spectrums, text summaries, transients, event logs and stored alarms
  • Print reports using standard or custom templates you design
Configure all functions of PEL-100Configure all functions of PEL-100

30 Day Load Study


The 30 Day Load Study has been released for the Power Energy Logger (PEL) Control Panel (Version 2.8.15349) in compliance with NEC Code 220.87.

NEW FEATURES include:

PEL-100 Device In FieldPEL-100 Device In Field

Configuration Screen

Version 2.8.15349 adds a new instrument type selection screen when adding a new instrument to the PEL Control Panel. Select the appropriate PEL instrument model when prompted by this window.

Information and Measurement ModesInformation and Measurement Modes
Max and Harmonic ModesMax and Harmonic Modes

30 Day Load Study Configuration Option

A checkbox labeled: 30 Day Load Study has been added to the recording tab of the configuration menu found inside the PEL Control Panel.


When selected, the recording will be automatically configured for a 30-day period, aggregate measurements into 15-minute periods, and recording options, including 1-second measurements and harmonics, will be inaccessible. This complies with the NEC Code 220.87.

Configure all functions of PEL-100Configure all functions of PEL-100

NEC 220 Article 220.87 30-Day Load Study Report Template

A new reporting template for load studies simplifies report creation for the PEL series of instruments. Once a recording is completed and added as a session to the Control Panel, a DataView® report can be created using the NEC 220.87 30 Day Load Study template. This report will populate peak power in kW and the max demand of the feeder or service as required by article 220.87.

Configure all functions of PEL-100Configure all functions of PEL-100

30-Day Load Study with Current Report Template

An additional new reporting template for load studies that populates peak power in kW and the max current demand for all phases has been added to the PEL Control Panel. Once a recording is completed and added as a session to the Control Panel, a DataView® report can be created using the 30 Day Load Study template.

Additional Features:

Support for Cloud services like OneDrive, Google Drive and DropBox for the DataView® documents folder.

  • A new screen to the installer process that shows how much hard drive space is available and how much it will take to install the application.
  • Now you have the ability to select the path to Download folder to store reports where you want on your PC.
  • Now you can see Model L452 data in the Workstation Instrument Panel view.
  • DataViewSync™ facilitates communication between the instrument and your computer to easily use DataView® to configure, analyze and generate reports. It also automates the selection of the server address and port.

Bug Fixes:

PEL-100 Series Comparison Chart


PEL-102, PEL-103 and PEL-105 StatisticsPEL-102, PEL-103 and PEL-105 Statistics

PEL-100 Series Catalog


PEL-100 Series Accessories


PEL-100 Series Product Videos